LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 1999 >> Century Custom >> Repair and Diagnosis >> Electrical >> Starter >> Starting System >> Bench Testing >> Solenoid Windings Tests >> Hold-In Windings Test

Hold-In Windings Test

  1. If solenoid is not removed from starter motor assembly, disconnect field lead from terminal "M" on solenoid and insulate field lead from solenoid motor terminal. Connect an ammeter and switch in series with 12-volt battery and starter solenoid terminal "S" as illustrated. See Fig 1. Connect a voltmeter between solenoid terminal "S" and ground. Connect a carbon pile across battery.
  2. Turn switch on and quickly adjust carbon pile load until voltage reads as specified. See HOLD-IN WINDINGS SPECIFICATIONS  table. Check ammeter reading. Turn off carbon pile and open switch. See HOLD-IN WINDINGS SPECIFICATIONS  table. If amperage reading is not as specified, replace starter.
Fig 1: Solenoid Winding Test Connections
G95G13470Courtesy of GENERAL MOTORS CORP.
HOLD-IN WINDINGS SPECIFICATIONS

Application Starter Motor Amps @ Volts
2.2L PG260 (1)
2.4L PG260, PG260MQ (1)
3.0L (1) (1)
3.1L
"N" Body PG260F1 (1)
"W" Body PG260F1 6-12 @ 10
3.4L PG260M1 (1)
3.5L PG260M1 6-12 @ 10
3.8L
"C", "F" & "H" Bodies PG260 5-15 @ 11.5
"G" Body (1) 5-15 @ 11.5
"W" Body PG260F2, PG260M 6-12 @ 10
4.0L (1) 5-15 @ 11.5
4.6L PG260 5-15 @ 11.5
5.7L PG260 5-15 @ 11.5
(1) Information is not available from manufacturer.