Diagnostic Aids
The following conditions may cause an intermittent: Intermittent open or short in circuit No. 1037 (Light Green wire) or No. 1049 (Dark Green wire), poor connections at BCM or PCM, or intermittent open in splice pack SP205. BCM may store DTC U1016 if certain diagnostics are performed between the PCM and Data Link Connector (DLC).