Circuit Description
Powertrain Control Module (PCM) supplies about .45 volt to Heated Oxygen Sensor 1 (HO2S 1). The HO2S 1 generates a voltage that varies from about one volt when exhaust is rich to about .10 volt when exhaust is lean. PCM monitors and stores sensor voltage information and evaluates the voltage samples to determine amount of time sensor voltage is out of range. If PCM detects HO2S 1 voltage remains at or near .45 volt for an extended period of time, DTC will set.