Removal & Installation
CAUTION:
When certain materials rub together, a transfer of electrons from one material to another may occur under special conditions. This results in an electrostatic charge (static electricity) being built up in one of the materials. When any conducting material comes in contact with the charged material, electrostatic discharge occurs, transferring electrons to the third material. Since electronic components used in control systems are designed to carry very low voltages, as little as a 30-volt charge created by static electricity can cause a total or degrading failure in ECM, BCM or other electronic components containing integrated circuits. Before servicing ECM or BCM, ground yourself and ground the work area to discharge stored electricity.
STATIC CHARGE (VOLTS)
| Type Of Movement | Relative Humidity 10-20% | Relative Humidity 65-90% |
|---|---|---|
| Walking Across Carpet | 35,000 | 1500 |
| Handling Clear Plastic Bag | 20,000 | 1200 |
| Sliding Across Velour Seat | 15,000 | 400 |
| Walking Across Tile/Vinyl | 12,000 | 50 |
| Handling Vinyl Envelope | 7000 | 600 |
CAUTION:
DO NOT remove part from packaging until ready to install. Ground any static-proof package PRIOR to opening. DO NOT touch electrical terminals of components unless properly grounded. DO NOT lay electrical components on car seat, carpeting or dashboard. Use electrostatic protection mat and ground strap whenever possible.