Programmer Indexing: Notes
PROGRAMMER ELECTRICAL INDEXING
| Application | Programmer | |
|---|---|---|
| Regal | ||
| Heater Control Valve | A | |
| A/C | B | |
| Defroster | C | |
| Heater | D | |
| Recirc. | E | |
| Ignition | F | |
| Skyhawk | ||
| Open | A | |
| Recirc. | B | |
| Defroster | C | |
| A/C | D | |
| Heater | E | |
| Ignition | F | |
- Check voltage at appropriate pin in 22-pin control panel connector. If voltage is less than 2 volts, check electrical connections and wiring between control panel and programmer. If voltage is more than 2 volts, replace control panel.
- Check voltage at appropriate pin in 22-pin control panel connector. If voltage is more than 2 volts, check electrical connections between control panel and programmer. If less than 2 volts, replace control panel.