Operating readiness
Operational status (operating readiness) depends on the terminal.
- Terminal 30B (basic operation) and terminal 30
The instrument cluster is connected to terminal 30B and terminal 30 via the life module power distribution box. The terminal status (Terminal R or Terminal 15) is made available to the instrument panel via the bus system. With Terminal 30 (Terminal R OFF), the instrument panel is in standby mode. Pressing the reset button wakens the instrument panel to display the following: Odometer, time display, ambient temperature, fuel level (can be encoded). The display goes out after 25 seconds.
- Terminal R
With terminal R On, the following are evaluated: Turn signal/high beam switch and fuel level sensor. The time and ambient temperature appear in the TFT display. The on-board computer functions can be started using the on-board computer button (display unlimited in time).
- Terminal 15
When Terminal 15 is switched ON, a pre-drive check is carried out on the permanent indicator and warning lights.