Service instruction
Starting the engine is only possible after terminal change. Otherwise only the starter motor turns over.
If the acceleration sensor is taught in, carry out the following measures:
- Register teach-in of the acceleration sensor in the engine control unit with the corresponding service function.
- Teach the acceleration sensor with the corresponding service function.
- Allow the vehicle to run at idle until the fault code entry is no longer currently present or is no longer entered again.
- Then clear fault memory.