Engine mount control: Function
The changeover valve connects the engine mounts to the vacuum supply. When activated by the DDE master control module, the changeover valve switches vacuum to the engine mounts which in turn switch to "soft".
The engine mounts are activated as follows:
- From "soft" to "hard" when 1050 rpm is exceeded
- From "hard" to "soft" when 950 rpm is not reached