LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2015 >> 528i >> Repair and Diagnosis (Single Page) >> Body & Frame >> Windows >> Body Equipment - Repair >> General >> 51 00... Notes on fitting window guide seals

51 00... Notes on fitting window guide seals

  1. Work safety when handling lubricant G13* 
    • Wear safety goggles, protective gloves and if necessary an apron.
    • Do not eat, drink or smoke in the area of processing/application
    • Ensure rooms are well ventilated.
    • Keep heat and ignition sources well away
    • In event of skin contact: Wash areas of skin affected with soap and water immediately, change work clothing which has been fouled with lubricant immediately (keep spare work clothing in reserve)
    • In event of eye contact: Rinse eyes immediately with plenty of water and seek medical advice
  2. General notes 
    • Use only the BMW-approved lubricant for fitting
    • Application only at room and object temperatures between 18 and 25 °C
    • Lubricant dries at different rates depending on the quantity, temperature and ventilation and becomes sticky
    • Lubricant can only be used for fitting and not for fault elimination (e.g. grating)
    • Newly painted parts may only be brought into contact with the lubricant after cooling
    • Optimal bonding/attachment to the background surface is achieved after approx. 48 hours. The window guide seal must not be exposed to mechanical strain beforehand (car wash, strength test, etc.).
    IMPORTANT: To avoid grating noises, do not use soapy water (low-surface-tension water with washing-up liquid) or lubricant containing silicone
  3. Auxiliary materials and tools 
  4. Preparations 
    • Heat and remove anti-friction agent residues with a hot air blower or clean new part thoroughly
    • Immediately prior to fitting, clean the work area in order to remove silicone and grease residues
    NOTE: Air drying time approx. 1 minute
  5. Installation 
    • Apply a thin coating of lubricant to the reverse side of the window guide seal only
    • Perform fitting within 30 minutes of applying lubricant
    • Lubricant dries after fitting and becomes sticky