32 41... Replacing level switch for Dynamic Drive fluid reservoir (N74)
Necessary preliminary tasks:
- Remove INTAKE DUCT for air filter housing
Release screws (1) and (2).
Tightening torque: see 21AZ in 32 41 PUMP AND OIL SUPPLY
NOTE:
Raise and/or turn fluid reservoir in order to gain better access to plug connection.
Disconnect plug connection (1).
Turn level switch (2) through approx. 45° and remove towards bottom.