Home >> BMW >> 2013 >> 740Li >> Repair and Diagnosis (Single Page) >> Electrical >> Charging Systems >> General Electrical System - Repair - F01/F02 >> Plug Connection, Terminal, Fuse Box >> 61 13... Installing fan connector for retrofitting/repairs >> Installation in wet area (engine compartment, wheel arch)

Installation in wet area (engine compartment, wheel arch)

Apply sealing compound on both sides and press into contacts (1).

Fit shrink-fit hose and heat up with hot air blower (2) (approx. 250 °C).

NOTE: Ensure that fan connector has sufficient contact surface on mounting point.

Do not heat shrink-fit hose on edges of fan connector too strongly, risk of cracking.

Allow shrink-fit hose to cool down until hand-warm. Then press sealing material again into contacts and onto edges of fan connector.

If necessary, carefully heat shrink-fit hose again.

Fig 1: Identifying Shrink-Fit Hose With Contacts
G06894978Courtesy of BMW OF NORTH AMERICA, INC.