Electrical power supply and specifications
Terminal 30B definition for basic operation:
Supply of energy to components required when the driver is present. Activated by driver action (lock activation, opening the door, etc.). Deactivation following shutdown phase (1 to 30 min. depending on status).
Observe the following nominal values for the brake light switch:
| Size | Value |
|---|---|
| Voltage range | 6 to 16 V |
| Current consumption in normal operating mode | ≤ 8 A |
| Output resistance, switch blocks | 1.5 MΩ |
| Temperature range | -40 to 85 deg C |