Digital data transmission by means of current interface
The recorded acceleration values of the micro-mechanical acceleration sensors are converted in an ASIC (Application Specific Integrated Circuit) into digital signals. With the aid of a data telegram, the digital signals are transmitted unidirectionally to the Crash Safety Module.
The signals are transmitted via a current interface, which supplies the electronic circuitry with voltage.
The electronic circuitry receives a voltage level of approximately 5-10 mA via the current interface. The level rises at a step of 20 mA when a data telegram is transmitted so that only two lines per measurement channel are required.
The transmitted data is evaluated in the crash safety module.