Home >> BMW >> 2012 >> 528i >> Repair and Diagnosis (Single Page) >> General Information >> OEM General Information >> Functional Description - F10 - Charging System, Anti-Theft System, Body Electrical System >> Charging System - Functional Description >> Charging pressure sensor (Ver. 2) >> Characteristic curve and setpoint values

Characteristic curve and setpoint values

The charging pressure information is sent to the engine control across a signal line. The signal for evaluation of the charging pressure fluctuates depending on the pressure. The measuring range of approx. 0.5 to 4.5 Volts corresponds to a charge-air pressure of 20 kPa (0.2 bar) to 250 kPa (2.5 bar).

Fig 1: Charge-Air Pressure Characteristic Curve
G09908200Courtesy of BMW OF NORTH AMERICA, INC.
Item Explanation
1 Voltage
2 Charge-air pressure characteristic curve
3 Pressure

Observe the following setpoint values for the charging pressure sensor:

Variable Value
Voltage range for charge-air pressure sensor 0.5 to 4.5 volts
Measuring range for charge-air pressure 0.2 to 2.5 bar
Maximum output current 10 mA
Temperature range -40 °C to 130 °C