LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2012 >> 335i 2D Convertible, Automatic Trans >> Repair and Diagnosis >> General Information >> OEM General Information >> Functional Descriptions - F25 - Cooling System, Engine Performance >> Cooling System - Functional Description >> Coolant temperature sensor (hybrid) >> Characteristic curve and setpoint values

Characteristic curve and setpoint values

The electrical voltage at the resistor is dependent on the coolant temperature. A table that specifies the temperature associated with each voltage value is stored in the engine control. This compensates for the non-linear relationship between electrical voltage and temperature.

Fig 1: Hot Conductor (NTC) Characteristic Curve
G09841354Courtesy of BMW OF NORTH AMERICA, INC.
Item Explanation
1 Voltage
2 Characteristic curve for hot conductor (NTC)
3 Temperature

Please note the following setpoint values for the coolant temperature:

Variable Value
Nominal resistance at 25 °C 2252 Ω ± 1.5 %
Power consumption 1 mA
Response time 15 s
Temperature resolution ±1 °C
Maximum output current 20 mA
Temperature range -40 °C to 150 °C