15.28.1 System Overview
Regarding the boost pressure control system the following comprehensive components are monitored:
- Electrical monitoring of all solenoid valves
- Functional response check of control flaps
- Control flap high pressure charger: Failure recognition with boost pressure governor deviation
- Control flap high pressure bypass: Failure recognition with boost pressure governor deviation
- Control flap wastegate (not emission relevant)