Check Control Message For Overheated Convertible Top Drive Motor (54 10 10)
Publication date: 2010-10-25Reference number: 54 10 10
CHECK CONTROL MESSAGE FOR OVERHEATED CONVERTIBLE TOP DRIVE MOTOR
TECHNICAL SERVICE BULLETIN
| BMW: | E88 (1 Series) up to June 14, 2010 production |
| GROUP: | Special Roofs |
SUBJECT
Check Control Message for Overheated Convertible Top Drive Motor
SITUATION
Intermittently a CC (Check Control) message is displayed, indicating overheating of the convertible top drive motor.
CAUSE
The convertible top module (CVM) coding
PROCEDURE
Perform diagnostics with ISTA, and then code the CVM with ISTA/P 2.38.1 or greater.
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty.
Defect Code: 61 35 49 15 00
| Labor Operation: | Labor Allowance: | Description: |
|---|---|---|
| 00 00 006* | Refer to KSD2 | Perform vehicle test |
| 61 00 710 | Refer to KSD2 | Program and Code with ISTA/P (w/o CAS) |
| 61 00 720 | Refer to KSD2 | Program and Code with ISTA/P (with CAS) |
| Refer to KSD2 | Refer to KSD2 | Concluding work (initializations) as described in ISTA/P final report |
*Main Work - Only one main labor operation (ending with 000-499) may appear on any claim or group of claims (warranty, maintenance or campaigns) that are generated from the same repair visit.
All other labor operations on the same line or other lines must be claimed using plus code labor operations (KSD2 labor operations that have a (+) prefix and the last three digits are 500 or a higher number).
In cases where ISTA requires the replacement of control modules or additional programming because certain control modules failed to program correctly, or just an initialization is required, print out the Measures Plan and/or Final Report and attach these reports to the RO in the vehicle file. This additional work should be claimed under the defect code listed in this bulletin, using the labor operation and labor allowance from the KSD2.