24 34 ... Notes On Mechatronics (GA6HP26Z/GA6HP32Z/GA6HP19Z)
Special tools required:
- 24 2 390
IMPORTANT:
After completing work:
- Load specific data version with DIS
- Check transmission fluid level See 00 11 500 CHECKING/TOPPING UP FLUID LEVEL IN AUTOMATIC TRANSMISSION (GA6HP26Z/6HP32Z)
Use only approved transmission fluid.
Failure to comply with this requirement will result in serious damage to the automatic transmission!
IMPORTANT:
Read and comply with notes on protection against electrostatic damage (ESD protection).
See 61 35 ... NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE)
Unscrew plug (1) and disconnect.
Insert special tool 24 2 390 in sealing sleeve (1). See 24 2 390 COVERING CAP