13 62 010 Removing And Installing/Replacing Differential Pressure Sensor (N62, N62TU)
Necessary preliminary tasks:
- Read out fault memory of Digital Motor Electronics (DME) control unit; if necessary, work through test schedules
- Switch off ignition
REFERENCE CHART
| Work step | Note: |
|---|---|
| Installation location: On rear side of intake air manifold. |
|
| Remove design cover. | E65/E66 only |
| Remove ACOUSTIC COVER . | |
| Remove BOTH LOWER MICROFILTER HOUSING SECTIONS . | E60/E61/E63/E64 only |
| Remove engine compartment bulkhead. | E65/E66 only |
| Remove cover for ignition coils on left and right. | |
Unlock and disconnect following plug connections.
|
Lines to oxygen sensors remain connected. Lines to electronics box remain connected. |
Unfasten screws.
Take off holder (4).
Lay cable ducts to one side.
Unlock plug (1) and remove.
Unfasten screws.
Pull differential pressure sensor (2) out of intake air manifold.
Installation:
Now clear the fault memory.