61 35 910 Removing and installing/replacing control unit of electronic immobilizer
IMPORTANT:
Read and comply with notes on protection against electrostatic damage (ESD protection). Refer to 61 35 ... NOTES ON ESD PROTECTION (ELECTRO STATIC DISCHARGE) .
Necessary preliminary tasks:
- Disconnect battery negative lead
- Remove trim panel for pedal assembly, refer to 51 45 185 REMOVING AND INSTALLING/REPLACING TRIM FOR PEDAL ASSEMBLY .
Unfasten plug connection (1) and disconnect.
NOTE:
Secure control unit of electronic immobilizer (3) against falling out.
Release screws (2) and remove control unit of electronic immobilizer (3).
Replacement:
Carry out programming/coding. Refer to Diagnosis Programming/Coding .