LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2004 >> 545i Standard >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel System - Repair >> Fuel Pump With Drive And Line >> 13 31 ... Notes on fuel pressure check (reference pressure: environment)

13 31 ... Notes on fuel pressure check (reference pressure: environment)

Feature Of This Version With Ambient Pressure: 

The connection for the vacuum hose of the fuel pressure regulator is located between the throttle and the air cleaner or on the air cleaner.

Test Precondition: 

The correct fuel pressure regulator is fitted.

Description Of Operation: 

The control function of the fuel pressure regulator must be guaranteed under all operating conditions. The fuel pump must always be able to generate a higher fuel pressure than the pressure regulated by the pressure regulator.

The injection rate is adjusted by means of the injection time; the injection time is controlled by the DME.

Description Of Operation: Fuel Return Line 

When the engine is at a standstill and the ignition key is in position 0, the fuel return line after the pressure regulator is at zero pressure.

Description Of Operation: Pressure Retaining Function 

The pressure regulator closes when the engine is at a standstill and the ignition key is in position 0. The fuel pressure in the delivery line is retained over an extended period. A non-return valve closes in the fuel pump. These measures help to retain the fuel pressure in the fuel system. Extended starting times are thus avoided.

Complaint: Drive Characteristic Faults, Lack Of Power 

If the measured value is less than the nominal value - 0.2 bar:

If the measured value is greater than the nominal value + 0.2 bar:

If measured value remains too high, then pressure regulator is in all probability faulty.

Important: 

With less likelihood, the return line may be completely blocked. When the pressure regulator is removed, fuel could escape under pressure!

Complaint: Starting Problems 

Special tool 13 3 010 (hose clamp) is required for the following test.

If The Measured Value Has Dropped By More Than 0.5 Bar: 

If The Measured Value Has Now Dropped By Less Than 0.5 Bar, The Following Faults Can Be Present: 

If The Measured Value Has Dropped By More Than 0.5 Bar Again: 

NOTE:
  • All the fuel hoses and hose clips which were detached within the framework of the checks must be replaced.
  • Interrogate fault memory of DME control unit. Check stored fault messages. Rectify faults. Now clear the fault memory.