Gt1 Test Plan Grayed Out And Not SELECTABLE (07 02 07)
Publication date: 2007-04-12Reference number: 07 02 07
GT1 TEST PLAN GRAYED OUT AND NOT SELECTABLE
TECHNICAL SERVICE BULLETIN
Reference Number(s): SI B 07 02 07, Date of Issue:
April, 2007
| BMW: | ALL |
| GROUP: | Workshop Environment Systems |
SUBJECT
GT1 Test Plan Grayed Out and Not Selectable
SITUATION
In some cases when a test plan in called up using the GT1 (Group Tester One), based upon fault or symptom selection, the test plan link is displayed but cannot be selected.
CAUSE
This is normal operation of the diagnostic software. Certain test plans require the use of the MIB (Measurement Interface Box) in order to properly complete the test plan.
PROCEDURE
Either connect the MIB to the GT1 or use the DISPlus to complete the test plan.
WARRANTY INFORMATION
For information only.