Scope Of Input Functions Bosch Oxygen Sensors: Notes
The MS42.0 system uses Bosch LSH 25 oxygen sensors that function basically the same as previously used (in Bosch systems). The voltage range is between 0 - 800 mV.
The location has changed, the pre-cat sensors are mounted on top of the exhaust manifolds. The catalysts are now integral with the exhaust manifolds.