LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2000 >> X5 >> Repair and Diagnosis (Single Page) >> Engine Performance >> Engine Control Systems >> Me 7.2 - Overview - X5, 5-Series, 7-Series >> Me 7.2 >> Output Control Functions/Components >> Auxiliary Fan Control

Auxiliary Fan Control

The Auxiliary Fan motor incorporates an output final stage that activates the fan motor at variable speeds.

The auxiliary fan is controlled by ME 7.2. The motor output stage receives power and ground and activates the motor based on a PWM signal (10 - 100 Hz) received from the ME 7.2.

The fan is activated based on the following factors:

Fig 1: Identifying Auxiliary Fan Control
G03394568Courtesy of BMW OF NORTH AMERICA, INC.

When the over temperature light in the instrument cluster is on (120°C) the fan is run in the overrun function. This signal is provided to the DME via the CAN bus. When this occurs the fan is run at a frequency of 10 Hz.

Fig 2: Identifying Auxiliary Fan Control Circuit
G03394569Courtesy of BMW OF NORTH AMERICA, INC.