Release Notes PROGMAN V20.0 And V20.0.1 (09 05 06)
Publication date: 2006-01-20Reference number: 09 05 06
RELEASE NOTES PROGMAN V20.0 AND V20.0.1
TECHNICAL SERVICE BULLETIN
Reference Number(s): SI B 09 05 06, Date of Issue:
January 20, 2006
| BMW: | All |
| GROUP: | Programming/Coding Explanation |
SUBJECT
Release Notes Progman V20.0 and V20.0.1
SITUATION
Progman V20.0 and V20.0.1 have been released. Certain errors may occur during installation or usage.
CAUSE
Software error
COMPLAINT
The following issues are currently known:
- "Back" button is missing after the "Change" button in the menu bar has been selected.
- E90: The programming of RAD2 Professional is shown in the final report with error 2020 (control unit not responding). Coding has error 1000 (general error).
- E90: MASK-S is not displayed as programmed in the final report and error 7022 (CoApi control unit communication problem) is displayed.
- The incorrect CIP version may be displayed on the "Online update" screen following a JET Stream update.
- GT1 may lock up after selecting the "Update software" button.
- E60, E63, E64: CCC-A and CCC-BO abort programming. The following error messages are shown: "7022 / 7032 / 7042 / 7098 (CoApi) - Control unit/programming system communication problem". and "1000 (CoApi) - General error".
- E85: The one-touch power windows function (opening/closing) may no longer be active after the general module has been replaced.
- When selecting "Cancel Update" after measures plan was displayed, an empty white screen may appear.
- Error message "The interface could not be assigned. (Code=42702, Msg=)" appears when using DK radio head. DK radio head cannot be assigned to PROGMAN session.
- After a new installation, the following error message may appear when searching for online updates even though the data has been transferred: "The SSS installation data could not be determined. (Code=45124, Msg=45042)."
- Progman session cannot be maximized. This error is indicated on the GT1 as a pop-up window and on the SSS as a white screen.
- After installation of the Base CD, the SSS may reboot two times instead of only once.
- E46: When attempting to import a new vehicle order (FA) via floppy disc, Progman states that "The vehicle order was successfully imported from the diskette", but the import was not successful.
- Online-updates are not downloaded automatically, even though the automatic update mode is shown as active in the "Installation" menu.
- E53: Buttons are shown twice in vehicle menu.
- The Progman V 20.0 installation aborts due to incorrect handling on the SSS R2 (copying error).
- Once the installation has been completed, the subsequent reboot of the SSS R1 may freeze.
- E65: CAS programming aborts.
- E53: Vehicles equipped with VVT cannot be programmed with Progman V20.0
PROCEDURE
- Button is hidden behind the "Minimise" button, no workaround.
- Start a new session after a battery reset and repeat programming/coding.
- MASK-S has been programmed nevertheless. Run additional measures plan to verify correct part number.
- Ignore the incorrect CIP version displayed.
- Disconnect the LAN-cable from the GT1.
- Wait 20 seconds or until message is displayed, that connection has been lost.
- Reconnect LAN-cable.
- Select "Update" at the SSS selection list.
- Select the SSS and continue programming session.
- Make sure the MOST connection of the OPS/OPPS is connected properly and repeat Programming/coding of the control module.
- Check the CKM settings and repeat window initialization.
- Wait until next screen is displayed. This may take a few minutes.
- Select Administration -> Interfaces -> select affected device -> Self test -> Accept. In case this procedure does not correct the problem, reboot the SSS and repeat this procedure.
- After a complete installation of Progman, the data in the "Online service" menu must be confirmed by pressing the "Continue" button. This will re-assign the online-update server.
- Reboot the GT1.
- The Progman DVD installation can be continued as usual even after two reboots.
- It is not possible to import a vehicle order via floppy disc for E46 vehicles.
- After a complete installation of Progman, the data in the "Online service" menu must be confirmed by pressing the "Continue" button. This will re-assign the online-update server. Select Administration -> Installation/Status -> Switch the automatic online update off and on again.
- Either one of the buttons can be used to select the function.
- After the basic CD has been successfully installed, it must be removed from the drive when it is automatically ejected. The empty drive must then be closed again. The Progman DVD must not be inserted until prompted on screen and the drive is opened again.
- Use the power button to reboot.
- Re-program the CAS again.
- Use GT1/DISplus not loaded with CIP. Correction expected with Progman V20.1.