Test 01: Roll Mode With System Test
This test conducts a short test of the instrument cluster. Once this test function is actuated, at display intervals of 3 seconds, the following information is displayed in trip odometer: MW scope of delivery (6 digits), code number of data set (5 digits), k-number (4 digits), a 6-digit number, software version (2 digits), then amendment index (2 digits). After this information has been displayed, all LED segments should illuminate and all gauges should sweep to limit position, then back to rest position. After gauges sweep back to rest position, test will be automatically terminated.