Distributor Cap & Rotor
- Remove distributor cover. Note location and pull off spark plug cables. Use Water Pump Pulley Holder (11-5-030) and remove LEFT-HAND threaded nut (turn clockwise to unscrew) from cooling fan.
- Remove bolts and push up fan cowl. Remove bolts and distributor. Using Allen wrench, remove rotor bolts and rotor. To install, reverse removal procedure. Tighten fan nut using 32-mm Fork Wrench (11-5-040) to 29 ft. lbs. (40 N.m). Firing order and cylinder numbers are marked on spark plug cables and cap.