Performance Characteristic Switchover For EH Transmission
During the shift procedure, the AEGS control unit sends a signal to the DME control units which set the ignition angle toward retard. This ensures a smooth transition to the newly selected drive range. As soon as the torque converter clutch unit is engaged, the DME control units are instructed to switch over to a different ignition angle characteristic.