LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2025 >> Q5 e Prestige >> Repair and Diagnosis >> Engine Performance >> System >> Generic Scan Tool (DSMA) (Transmission - Battery Charger Control Module DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Transmission DTC Tables >> Transmission Control Module -- DL382E - 7A (7 SPEED) 0CJC, 2024 MY

Transmission Control Module -- DL382E - 7A (7 SPEED) 0CJC, 2024 MY

Component / System DTC / DTC Description Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Conditions Monitoring Time Length MIL Illum.
Gear Shift Module 1-3 P2832 - Shift Fork "A" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 4-6 P2841 - Shift Fork "D" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 5-7 P283C - Shift Fork "C" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 2-R P2837 - Shift Fork "B" Position Circuit Range/Performance Signal range check Duty-Cycle of Position sensor > 92.5 [%] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Duty-Cycle of Position sensor < 7.5 [%]          
Gear Shift Module 1-3 P2831 - Shift Fork "A" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 4-6 P2840 - Shift Fork "D" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 5-7 P283B - Shift Fork "C" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 2-R P2836 - Shift Fork "B" Position Circuit Signal range check No signal received for > 1 [s]     [-] 2 [s] Continuous 2 DCY
Gear Shift Module 1-3 P2832 - Shift Fork "A" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Time of oscillation > 1.1 [ms]          
Gear Shift Module 4-6 P2841 - Shift Fork "D" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Time of oscillation > 1.1 [ms]          
Gear Shift Module 5-7 P283C - Shift Fork "C" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Time of oscillation > 1.1 [ms]          
Gear Shift Module 2-R P2837 - Shift Fork "B" Position Circuit Range/Performance Signal range check Time of oscillation < 0.9 [ms] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Time of oscillation > 1.1 [ms]          
Speed Sensor Shaft 1 P0718 - Input/Turbine Shaft Speed Sensor "A" Circuit Intermittent Rationality check No signal > 1 [s] Ignition On [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 2 P2768 - Input/Turbine Shaft Speed Sensor "B" Circuit Intermittent Rationality check No signal > 1 [s] Ignition On [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 1 P0501 - Vehicle Speed Sensor "A" Circuit Range/Performance Rationality check Difference between measured and calculated output speed for shaft 1 > 150 [rpm] Input shaft speeds for shafts 1 and 2 > 100 [rpm] 2 [s] Continuous 2 DCY
  and Difference between output shaft speed 1 and shaft 2 > 150 [rpm]          
Speed Sensor Shaft 2 P2159 - Vehicle Speed Sensor "B" Circuit Range/Performance Rationality check Difference between measured and calculated output speed for shaft 2 > 150 [rpm] Input shaft speeds for shafts 1 and 2 > 100 [rpm] 2 [s] Continuous 2 DCY
  and Difference between output shaft speed 1 and shaft 2 > 150 [rpm]          
Speed Sensor Shaft 1 and Shaft 2 P2162 - Vehicle Speed Sensor "A"/"B" Correlation Rationality check Difference between output shaft speeds and input speeds shafts 1 and 2 > 150 [rpm] Input shaft speeds for shafts 1 and 2 > 100 [rpm] 2 [s] Continuous 2 DCY
        and Engaged gear position is not Neutral [-]    
TCM Temperature Sensor P0666 - Control Module Internal Temperature Sensor "A" Circuit Circuit continuity check TCM Temperature Sensor self check and TCM Temperature Sensor failed invalid state [-] [-] Ignition and TCM Temperature Sensor Initialization On Finished [-] [-] 2 [s] Continuous 2 DCY
Circuit continuity check TCM Temperature Sensor at -0.03125 [°C] Ignition On [-] 2 [s] Continuous 2 DCY
  and Actual chip temperature < -24 [°C] and TCM Temperature Sensor Initialization Finished [-]    
  or Actual chip temperature > 24 [°C]          
P0667 - Control Module Internal Temperature Sensor "A" Range/Performance Rationality check Difference between TCM Temperature Sensor and internal 26 > x > -26 [°C] Ignition On [-] 2 [s] Continuous 2 DCY
  chip temperature     and TCM Temperature Sensor Initialization Finished [-]    
Rationality check Difference between actual TCM Temperature Sensor and filtered temperature > 8 [°C] Ignition On [-] 2 [s] Continuous 2 DCY
P0713 - Transmission Fluid Temperature Sensor "A" Circuit High Circuit continuity check Short circuit to high > 4.7 [V] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
P0712 - Transmission Fluid Temperature Sensor "A" Circuit Low Circuit continuity check Short circuit to ground < 0.16 [V] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance Rationality check Actual ATF temperature > 170 [°C] Power supply voltage 6•••18 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Actual ATF temperature < -50 [°C]          
Circuit continuity check Difference between actual ATF temperature and filtered temperature > 15 [°C] Power supply voltage 6•••18 [V] 2 [s] Continuous 2 DCY
ATF Pump Speed Sensor P0C2D - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Low Signal range check Sensor output voltage < 0.25 [V] Sensor supply voltage 4.5•••5.5 [V] 2 [s] Continuous 2 DCY
P0C2E - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal High Signal range check Sensor output voltage > 4.5 [V] Sensor supply voltage 4.5•••5.5 [V] 2 [s] Continuous 2 DCY
P0C2C - Electric/Auxiliary Transmission Fluid Pump Control Module Feedback Signal Range/Performance Rationality check Sensor output sin2 +cos2 > 0.8 [-] Sensor supply voltage 4.5•••5.5 [V] 2 [s] 2 DCY
              Continuous  
  or              
  Sensor output sin2 +cos2 < 1.2 [-]          
TCM Temperature Sensor P0711 - Transmission Fluid Temperature Sensor "A" Circuit Range/Performance Rationality check Difference between ATF temperature and TCM temperature > 20 [K] Deviation between temperature measured at the transmission control module (TCM) printed circuit board (PCB) and temperature measured in automatic transmission fluid (ATF) oil after a longer term of transmission cool down. Too high [-] 0.0 [s] Once / DCY 2 DCY
Electrical Pump P1A7D - Electr. pump 3 for transmission Temperature implausible Rationality Check The ATF auxiliary pump temperature signal Invalid [-] LIN communication and Active [-] 5 [s] Continuous 2 DCY
        Temperature sensor error flag Not set [-]    
Supply Voltage Monitoring Stage 3 P06D5 - Sensor Reference Voltage "E" Circuit Range/Performance Signal range check Internal sensor supply voltage > 5.5 [V]     [-] 2 [s] Continuous 2 DCY
  or Internal sensor supply voltage < 4.5 [V]      
(Electrical) ATF Pump P0C2A - Electric/Auxiliary Transmission Fluid Pump Motor Stalled Functional check Current ATF pump speed 300 [rpm] ATF pump governor Enabled   2 [s] Continuous 2 DCY
  and Set current for ATF pump control 30•••50 [A] and Target ATF-engine speed 300 [rpm]    
P0B0D - Electric/Auxiliary Transmission Fluid Pump Motor Control Module Signal range check Difference between actual and commanded ATF pump speed > 500 [rpm] Calibration Not active [-] 2 [s] Continuous 2 DCY
P0C28 - Electric/Auxiliary Transmission Fluid Pump Motor Current High Functional check ATF pump overcurrent protection active [-] Ignition On [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module P0C29 - Electric/Auxiliary Transmission Fluid Pump Driver Circuit Performance Circuit continuity check electrical failure in power amplifier Detected [-]     [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module Circuit continuity check Driver error Detected [-]     [-] 2 [s] Continuous 2 DCY
(Electrical) ATF Pump Control Module Circuit continuity check Overload ATF pump Detected [-]     [-] 2 [s] Continuous 2 DCY
Solenoid for gear 1-3 P0750 - Shift Solenoid "A" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for gear 4-6 P0765 - Shift Solenoid "D" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and        
        Belonging common high side switch Active [-]    
Solenoid for gear 5-7 P0760 - Shift Solenoid "C" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for gear 2-R P0755 - Shift Solenoid "B" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for clutch 1 P0745 - Pressure Control Solenoid "A" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for clutch 2 P0775 - Pressure Control Solenoid "B" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for main pressure P0795 - Pressure Control Solenoid "C" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for cooling P0770 - Shift Solenoid "E" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for overpressure reduction P2706 - Shift Solenoid "F" Circuit continuity check Difference between set current and measured current. > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Solenoid for disconnect clutch P287F - Engine Disconnect Clutch Actuator Circuit Range/Performance Circuit continuity check Difference between set current and measured current > 100 [mA] Circuits for activation and deactivation of the transmission solenoid driver (SDS4) actuators Active [-] 2 [s] Continuous 2 DCY
        and No transmission solenoid driver (SDS4) error Detected [-]    
        and Belonging common high side switch Active [-]    
Gear Actuator 1-3 P284D - Shift Fork "A" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Unrequested Movement Functional check Loaded gear leaves the engage- position > 3 [mm] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 1-3 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 4-6 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 5-7 nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time out in gear actuator state after synchronization > 1 [s] Gear actuator 2-R nominal state is After synchronization [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 1-3 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 4-6 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 5-7 nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 2-R nominal state is Unlatched [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time out in gear actuator state Unlatched > 1 [s] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time out in gear actuator state Engage > 1 [s] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P2845 - Shift Fork "A" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 1-3 leaves the neutral-position > 3 [mm] Gear actuator 1-3 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2848 - Shift Fork "D" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 4-6 leaves the neutral-position > 3 [mm] Gear actuator 4-6 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P2847 - Shift Fork "C" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 5-7 leaves the neutral-position > 3 [mm] Gear actuator 5-7 nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P2846 - Shift Fork "B" Position Sensor Incorrect Neutral Position Indicated Functional check Gear actuator 2-R leaves the neutral-position > 3 [mm] Gear actuator 2-R nominal state is Neutral [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P284D - Shift Fork "A" Unrequested Movement Functional check Gear actuator 1-3 leaves the engage-position > 1 [s] Gear actuator 1-3 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P2850 - Shift Fork "D" Unrequested Movement Functional check Gear actuator 4-6 leaves the engage-position > 1 [s] Gear actuator 4-6 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284F - Shift Fork "C" Unrequested Movement Functional check Gear actuator 5-7 leaves the engage-position > 1 [s] Gear actuator 5-7 nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284E - Shift Fork "B" Unrequested Movement Functional check Gear actuator 2-R leaves the engage-position > 1 [s] Gear actuator 2-R nominal state is Engaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P2849 - Shift Fork "A" Stuck Functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 1-3 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P284C - Shift Fork "D" Stuck Functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 4-6 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P284B - Shift Fork "C" Stuck Functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 5-7 nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P284A - Shift Fork "B" Stuck Functional check Time out in gear actuator state Disengage > 2 [s] Gear actuator 2-R nominal state is Disengaged [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Time out in gear actuator state synchronize > 2 [s] Gear actuator 1-3 nominal state is synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Time out in gear actuator state synchronize > 2 [s] Gear actuator 4-6 nominal state is synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Time out in gear actuator state synchronize > 2 [s] Gear actuator 5-7 nominal state is synchronized [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Time out in gear actuator state synchronize > 2 [s] Gear actuator 2-R nominal state is synchronized [-] 2 [s] Continuous 2 DCY
Drive-Off Clutch 1 P0811 - Excessive Clutch "A" Slippage Functional check Clutch slippage was detected > 150 [rpm] Clutch state is Drive [-] 2 [s] Continuous 2 DCY
Drive-Off Clutch 2 P081E - Excessive Clutch "B" Slippage Functional check Clutch slippage was detected > 150 [rpm] Clutch state is Drive [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 1 P0716 - Input/Turbine Shaft Speed Sensor "A" Circuit Range/Performance Signal range check Input shaft speed for shaft 1 > 12000 [rpm]     [-] 2 [s] Continuous 2 DCY
Speed Sensor Shaft 2 P2766 - Input/Turbine Shaft Speed Sensor "B" Circuit Range/Performance Signal range check Input shaft speed for shaft 2 > 12000 [rpm]     [-] 2 [s] Continuous 2 DCY
Solenoid for gear 1-3 P0753 - Shift Solenoid "A" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 1 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 1 and Common low side for the magnetic valve 1 and Electric current of the magnetic valve 1 or Error at the magnetic valve 1 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for gear 5-7 P0763 - Shift Solenoid "C" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 3 and Common low side for the magnetic valve 3 and Electric current of the magnetic valve 3 or Error at the magnetic valve 3 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 1 P0748 - Pressure Control Solenoid "A" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 1 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 1 and Ready Finished [-] [-] 2 [s] Continuous 2 DCY
        Common low side for the magnetic valve 1 and Electric current of the magnetic valve 1 or Error at the magnetic valve 1 Active >= 200 Detected [-] [mA] [-]    
Solenoid for overpressure reduction P2709 - Shift Solenoid "F" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 6 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 6 and Common low side for the magnetic valve 6 and Electric current of the magnetic valve 6 or Error at the magnetic valve 6 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for gear 2-R P0758 - Shift Solenoid "B" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 2 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 2 and Common low side for the magnetic valve 2 and Electric current of the magnetic valve 2 or Error at the magnetic valve 2 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for gear 4-6 P0768 - Shift Solenoid "D" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 3 and Common low side for the magnetic valve 3 Ready Finished Active [-] [-] [-] 2 [s] Continuous 2 DCY
        and Electric current of the magnetic valve 3 or Error at the magnetic valve 3 >= 200 Detected [mA] [-]    
Solenoid for clutch 2 P0778 - Pressure Control Solenoid "B" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 2 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 2 and Common low side for the magnetic valve 2 and Electric current of the magnetic valve 2 or Error at the magnetic valve 2 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for disconnect clutch P2880 - Engine Disconnect Clutch Actuator Circuit Low Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 2 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 2 and Common low side for the magnetic valve 2 and Electric current of the magnetic valve 2 or Error at the magnetic valve 2 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
Solenoid for main pressure P0798 - Pressure Control Solenoid "C" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 3 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 3 and Common low side for the magnetic valve 3 and Ready Finished Active [-] [-] [-] 2 [s] Continuous 2 DCY
        Electric current of the magnetic valve 3 or Error at the magnetic valve 3 >= 200 Detected [mA] [-]    
Solenoid for cooling P0773 - Shift Solenoid "E" Electrical Circuit continuity check Internal voltage Failure [-] Hardware module to control the magnetic valve 5 and transmission solenoid driver (SDS4) test sequence for the magnetic valve 5 and Common low side for the magnetic valve 5 and Electric current of the magnetic valve 5 or Error at the magnetic valve 5 Ready Finished Active >= 200 Detected [-] [-] [-] [mA] [-] 2 [s] Continuous 2 DCY
TCM internal driver A P0702 - Transmission Control System Electrical Circuit continuity check Internal voltage Failure [-] Transmission solenoid driver (SDS4) A monitoring and Error in the supply voltage of the transmission solenoid driver (SDS4) A and State of the transmission solenoid driver (SDS4) A switch off path Active Not detected Active [-] [-] [-] 2 [s] Continuous 2 DCY
TCM internal driver B Circuit continuity check Internal voltage Failure [-] Transmission solenoid driver (SDS4) B monitoring and Error in the supply voltage of the transmission solenoid driver (SDS4) B and State of the transmission solenoid driver (SDS4) B switch off path Active Not detected Active [-] [-] [-] 2 [s] Continuous 2 DCY
TCM internal driver C Circuit continuity check Internal voltage Failure [-] Transmission solenoid driver (SDS4) C monitoring and Active [-] 2 [s] Continuous 2 DCY
        Error in the supply voltage of the transmission solenoid driver (SDS4) C and State of the transmission solenoid driver (SDS4) C switch off path Not detected Active [-] [-]    
TCM P0700 - Transmission Control System (MIL Request) Functional check Central processing unit (CPU) permanent shutdown of all actors Detected [-]     [-] 2 [s] Continuous 2 DCY
P062F - Internal Control Module EEPROM Error Rationality check Comparison of EEProm date - both copies Invalid [-] Reading operation of data block Active [-] 2 [s] Continuous 2 DCY
Memory check Comparison of stored value - both copies Invalid [-] Reading operation of data block Active [-] 2 [s] Continuous 2 DCY
Memory check Write ability check Failed [-]     [-] 2 [s] Continuous 2 DCY
P0701 - Transmission Control System Range/Performance Functional check Repeated malfunctions at switch off path check (SOPC) Detected [-]       2 [s] Once / DCY 2 DCY
Supply Voltage Monitoring Stage 1 P0560 - System Voltage Signal range check Internal sensor supply voltage or Internal sensor supply voltage > 5.5 < 4.5 [V] [V]     [-] 2 [s] Continuous 2 DCY
Supply voltage Monitoring Stage 2 Signal range check Internal sensor supply voltage or Internal sensor supply voltage > 5.5 < 4.5 [V] [V]     [-] 2 [s] Continuous 2 DCY
TCM internal driver A P06A6 - Sensor Reference Voltage "A" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver A is Set [-] Transmission solenoid driver (SDS4) A monitoring Active [-] 2 [s] Continuous 2 DCY
TCM internal driver B P06A7 - Sensor Reference Voltage "B" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver B is Set [-] Transmission solenoid driver (SDS4) B monitoring Active [-] 2 [s] Continuous 2 DCY
TCM internal driver C P06A8 - Sensor Reference Voltage "C" Circuit Range/Performance Circuit continuity check Internal error flag on solenoid driver C is Set [-] Transmission solenoid driver (SDS4) C monitoring Active [-] 2 [s] Continuous 2 DCY
Supply Voltage Monitoring P06A9 - Sensor Reference Voltage "D" Circuit Range/Performance Signal range check Internal sensor supply voltage < 9 [V]     [-] 2 [s] Continuous 2 DCY
P0562 - System Voltage Low Signal range check Supply Voltage < 8 [V]     [-] 5 [s] Continuous 2 DCY
  and one of the following monitors P0750, P0765, P0760, P0755, P0745, P0775, P0795, P0770, P2706 protective function is Active [-]          
(Electrical) ATF Pump P0B0A - Electric/Auxiliary Transmission Fluid Pump Motor Supply Voltage Circuit Low Signal range check Supply Voltage and P0B0D protective function is < 10 Active [V] [-] Ignition On [-] 2 [s] Continuous 2 DCY
Supply Voltage Monitoring P0563 - System Voltage High Signal range check Supply Voltage > 18 [V]     [-] 2 [s] Continuous 2 DCY
FlexRay U0110 - Lost Communication With Drive Motor Control Module "A" Communication check Messages from Drive Motor Control Module "A" Not Received [-] Ignition On [-] 2 [s] Continuous 2 DCY
U0151 - Lost Communication With Restraints Control Module Communication check Communication with restraints control module Failed [-] Ignition On [-] 2 [s] Continuous 2 DCY
Electric Clutch Between Engine And Drive Motor P2882 - Engine Disconnect Clutch Excessive Slippage Functional check Torque reduction for combustion engine due to slip at hybrid clutch below a certain value of max torque < 80 [%] Ignition On [-] 5 [s] Continuous 2 DCY
P2886 - Engine Disconnect Clutch Stuck Closed Functional check Internal combustion engine speed despite open commanded hybrid clutch, internal combustion engine speed integral higher than a certain value > 30 [rpm*s] Adaption of electric clutch between engine and drive motor Not active [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 1 P0747 - Pressure Control Solenoid "A" Stuck On Functional check Difference in actual pressure on clutch K1 compared to the requested pressure on clutch K1 Detected [-]     [-] 2 [s] Continuous 2 DCY
Solenoid for clutch 2 P0777 - Pressure Control Solenoid "B" Stuck On Functional check Difference in actual pressure on clutch K2 compared to the requested pressure on clutch K2 Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM P060B - Internal Control Module A/D Processing Performance Rationality check Repeated implausible sensor signal Detected [-]     [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Traction in the opposite driving direction Detected [-]     [-] 2 [s] Continuous 2 DCY
Functional check Selection of too low gear and clutch Detected Closed [-] [-]     [-] 2 [s] Continuous 2 DCY
Functional check Selection of too low gear Detected [-]     [-] 2 [s] Continuous 2 DCY
Rationality check A very low gear and abnormal deceleration due to the hybrid clutch being Engaged Closed [-] [-]     [-] 2 [s] Continuous 2 DCY
TCM P2C83 - Cold Start Shift Time Too Short Functional check Engine minimum speed requirement, sent from Engine Control Module (ECM) to Transmission Control Module (TCM) during cold start Not satisfied [-] No transmission malfunction that reduces the available gears and gear selection is and a minimum speed requirement caused by Cold Start Emission Reduction Strategy (CSERS) by Transmission Control Module (TCM) is Detected D or S Received [-] [-] [-] Once / DCY 2 DCY
P0895 - Shift Time Too Short Functional check Engine minimum speed requirement, sent from Engine Control Module (ECM) to Transmission Control Module (TCM) because of an OBD relevant measure (not Cold Start Emission Reduction Strategy (CSERS)) Not satisfied [-] No transmission malfunction that reduces the available gears and gear selection is and a minimum speed requirement caused by an OBD relevant measure (not Cold Start Emission Reduction Strategy (CSERS)) by Transmission Control Module (TCM) is Detected D or S Received [-] Multiple 2 DCY
Electric Clutch Between Engine And Drive Motor P0A0F - Engine Failed to Start Functional check Number of moment increases and K0 clutch temperature and failure flag engine torque and failure flag clutch too high too high Active Active [-] [-] [-] [-] Hybrid clutch K0 charging state or Hybrid clutch K0 dragstart state and no combustion engine speed Active Active Detected [-] [-] [-] 2 [s] Continuous 2 DCY
TCM Safety monitor P0607 - Control Module Performance Functional check Engagement of two gears on one shaft Detected [-]     [-] 2 [s] Continuous 2 DCY
Electrical Pump P195F - Electr. pump 3 for transmission Supply voltage too low Rationality check Test for supply voltage too low Failed [-] Ignition and LIN-communication error and Automatic Transmission Fluid Pump 2 (ATFP2-pump) and power supply voltage On Not active On 8•••18 [-] [-] [-] [V] 5 [s] Continuous 2 DCY
P196A - Electr. pump 3 for transmission Supply voltage too high Rationality check Test for supply voltage too low Failed [-] Ignition and LIN-communication error and Automatic Transmission Fluid Pump 2 (ATFP2-pump) and power supply voltage On Not active On 8•••18 [-] [-] [-] [V] 0...5 [s] Continuous 2 DCY
U13E9-Electr. pump 3 for transmission no communication Communication check Pump communication Failed [-] Ignition and Automatic Transmission Fluid Pump 2 (ATFP2-pump) and power supply voltage On On 8•••18 [-] [-] [V] 0...5 [s] Continuous 2 DCY
P196B - Electr. pump 3 for transmission No function Functional check Parameter set or Overcurrent check or Wrong Failed [-] [-] Ignition and LIN-communication error and On Not active [-] [-] 0...5 [s] Continuous 2 DCY
  Rotor Blocked [-] Automatic Transmission Fluid Pump 2 (ATFP2-pump) and power supply voltage On 8•••18 [-] [V]    
P196C - Electr. pump 3 for transmission Mechanical malfunction Functional check MosFET or Controller or Watchdog or Temperature sensor or Position sensor Defect Defect Error Defect Defect [-] [-] [-] [-] [-] Ignition and Functional fault and LIN communication error and Automatic Transmission Fluid Pump 2 (ATFP2-pump) and Power supply voltage On Not active Not active On 8•••18 [-] [-] [-] [-] [V] 0...5 [s] Continuous 2 DCY
P196B - Electr. pump 3 for transmission No function Functional check Test for speed Failed [-] Ignition and Functional fault and Hardware malfunction and Overtemperature and LIN communication error and Automatic Transmission Fluid Pump 2 (ATFP2-pump) and Power supply voltage On Not Active Not Active Not Active Not Active On 8•••18 [-] [-] [-] [-] [-] [-] [V] 0...5 [s] Continuous 2 DCY
TCM P1A7E - Activation of electrical pump 3 for transmission oil No function Circuit continuity Check Short circuit of Automatic Transmission Fluid Pump 2 (ATFP2-pump) Pump-On-Pin to Low Detected [-] Ignition On [-] 2 [s] Continuous 2 DCY
Circuit continuity Check Short circuit of Automatic Transmission Fluid Pump 2 (ATFP2-pump) Pump-On-Pin to High Detected [-] Ignition On [-] 2 [s] Continuous 2 DCY
Electrical Pump P1A7D - Electr. pump 3 for transmission Temperature implausible Rationality check ATF auxiliary pump temperature signal Implausible [-] Ignition and On [-] 0 [s] Once / DCY 2 DCY
        Deviation between temperature transmitted by ATF auxiliary pump (via LIN) and temperature measured within the TCU after a longer term of transmission cool down Too high [-]    
TCM Safety monitor P0607 - Control Module Performance Functional check Closure of both clutches Detected [-]     [-] 2 [s] Continuous 2 DCY
Functional check Incorrect clutch actuation Detected [-]     [-] 2 [s] Continuous 2 DCY
Flexray U0080 - Vehicle Communication Bus F Communication check No Flexray synchronisation Detected [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM U0100 - Lost Communication With ECM/PCM "A" Communication check Engine Control Module No signal [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ABS U0121 - Lost Communication With Anti-Lock Brake System (ABS) Control Module "A" Communication check Anti-Lock Brake System No signal [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM U0401 - Invalid Data Received From ECM/PCM "A" Communication check Data received from Engine Control Module Invalid [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ABS U0415 - Invalid Data Received from Anti-Lock Brake System (ABS) Control Module "A" Communication check Data received from Anti-Lock Brake System Invalid [-] Ignition On [-] 2 [s] Continuous 2 DCY
Flexray Signal from ECM P0614 - ECM/TCM Incompatible Rationality check Information of engine code Faulty [-] Ignition On [-] 2 [s] Continuous 2 DCY
Rationality check Information of transmission code Faulty [-] Ignition On [-] 2 [s] Continuous 2 DCY
TCM U1103-Production mode active Functional check Production mode active [-] Ignition On [-] 2 [s] Continuous 2 DCY
Gear Actuator 1-3 P187A - Gear selector 1 Engaging process not successful Functional check Difference between measured and synchronized shaft speed 1 and gear actuator 1-3 movement or gear actuator 1-3 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Gear Actuator 4-6 P187D - Gear selector 4 Engaging process not successful Functional check Difference between measured and synchronized shaft speed 2 and gear actuator 4-6 movement or gear actuator 4-6 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Gear Actuator 5-7 P187C - Gear selector 3 Engaging process not successful Functional check Difference between measured and synchronized shaft speed 1 and gear actuator 5-7 movement or gear actuator 5-7 movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Gear Actuator 2-R P187B - Gear selector 2 Engaging process not successful Functional check Difference between measured and synchronized shaft speed 2 and gear actuator 2-R movement or gear actuator 2-R movement > 300 > 7 < -7 [rpm] [mm] [mm] Shaft 1 and 2 In sync position [-] 2 [s] Continuous 2 DCY
Flexray Signal from ABS C0501 - Left Front Wheel Speed Sensor "A" Range/Performance Signal range check Front left wheel speed sensor signal Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C0507 - Right Front Wheel Speed Sensor "A" Range/Performance Signal range check Front right wheel speed sensor signal Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C050D - Left Rear Wheel Speed Sensor "A" Range/Performance Signal range check Rear left wheel speed sensor signal Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C0513 - Right Rear Wheel Speed Sensor "A" Range/Performance Signal range check Rear right wheel speed sensor signal Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C0032 - Left Front Wheel Speed Sensor Supply Signal range check Front left wheel speed sensor undervoltage Detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C0035 - Right Front Wheel Speed Sensor Supply Signal range check Front right wheel speed sensor undervoltage Detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C0038 - Left Rear Wheel Speed Sensor Supply Signal range check Rear left wheel speed sensor undervoltage Detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C003B - Right Rear Wheel Speed Sensor Supply Signal range check Rear right wheel speed sensor undervoltage Detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
C051D - Multi-axis Acceleration Sensor Module "A" Missing Calibration Signal range check Longitudinal acceleration sensor Not calibrated [-] Ignition On [-] 5 [s] Continuous 2 DCY
C051C - Multi-axis Acceleration Sensor Module "A" Range/Performance Signal range check Longitudinal acceleration sensor Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
Flexray Signal from Restraints Control Module C0552 - Longitudinal Acceleration Sensor Range/Performance Rationality check Offset of longitudinal acceleration signal 1.1 [m/s2] Ignition On [-] 5 [s] Once / DCY 2 DCY
Signal range check State of longitudinal acceleration signal Error detected [-] Ignition On [-] 5 [s] Continuous 2 DCY
Flexray Signal from ABS C0505 - Left Front Wheel Speed Sensor "A" Correlation Rationality check Deviation of front left wheel speed from vehicle speed during static straight-line travel 2 [km/h] Static straight-line travel 20•••150 [km/h] 5 [s] Continuous 2 DCY
C050B - Right Front Wheel Speed Sensor "A" Correlation Rationality check Deviation of front right wheel speed from vehicle speed during static straight-line travel 2 [km/h] Static straight-line travel 20•••150 [km/h] 5 [s] Continuous 2 DCY
C0511 - Left Rear Wheel Speed Sensor "A" Correlation Rationality check Deviation of rear left wheel speed from vehicle speed during static straight-line travel 2 [km/h] Static straight-line travel 20•••150 [km/h] 5 [s] Continuous 2 DCY
C0517 - Right Rear Wheel Speed Sensor "A" Correlation Rationality check Deviation of rear right wheel speed from vehicle speed during static straight-line travel 2 [km/h] Static straight-line travel 20•••150 [km/h] 5 [s] Continuous 2 DCY