LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2021 >> SQ7 Premium Plus >> Repair and Diagnosis >> Maintenance >> Procedures >> General Information >> General Information >> Maintenance Work >> Battery Transport Mode, Deactivating

Battery Transport Mode, Deactivating

CAUTION:

Risk of injury due to unintended engine start on high-voltage vehicles!

  • Pay attention to the high-voltage system warning messages:
  • For procedures where the ignition must be switched off.
NOTE:

The Full pre-delivery inspection  test program may also be performed as part of the pre-delivery inspection.

Procedure: 

-- Connect the Vehicle Diagnostic Tester. Refer to VEHICLE DIAGNOSTIC TESTER, CONNECTING .

-- Select the Diagnostic  mode and start the diagnosis.

-- Perform the vehicle identification.

-- Deselect "Working with Guided Fault Finding" by removing and pressing Accept  .

-- Switch to the "Special Functions" tab and select the following program:

-- Start the program using Perform test...  .

-- Continue the program sequence.

NOTE:

Battery transport mode ensures that the vehicle will be able to start.

When battery transport mode is on, many functions such as the radio do not work or are limited.