LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2021 >> A8 e Quattro >> Repair and Diagnosis >> Transmission >> Transmission Control Systems >> Generic Scan Tool [CZSE] (Hybrid) (Brake System Control Module (C0512 - U0431) - Gateway DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Gateway DTC Tables >> Gateway Module --, 2021 MY

Gateway Module --, 2021 MY

Component / System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor Frequency of Checks Monitoring Time Length Unit MIL Illum.
Hybrid CAN U014B Lost communication with control module for contact-less charging (time out) Message time out = detected [-] Ignition = on [-] continuous 2, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0112 Lost communication with Battery Energy Control Module "B" (time out) Message time out = detected [-] Ignition = on [-] continuous 870 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0112 Lost communication with Battery Energy Control Module "B" (time out) Message time out = detected [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0112 Lost communication with Battery Energy Control Module "B" (time out) Message time out = detected [-] Driving mode = active [-] continuous 5, 370 [ms] 1 DCY
  U0110 Lost communication with Drive Motor Control Module "A" (time out) Message time out = detected [-] [(Ignition = on [-] continuous 1, 645 [ms] 1 DCY
    OR            
    Autonomous HV request) = commanded on          
    Driving mode] = not active          
    OR            
    Driving mode = active [-] continuous 5, 370 [ms] 1 DCY
  U0110 Lost communication with Drive Motor Control Module "A" (time out) Message time out = detected [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U019B Lost communication with Battery Charger Control Module "A" (time out) Message time out = detected [-] Ignition = on [-] continuous 1, 420 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0116 Lost communication with Coolant Temperature Control Module (time out) Message time out = detected [-] Driving mode = active [-] continuous 370 [ms] 2 DCY
  U0116 Lost communication with Coolant Temperature Control Module (time out) Message time out = detected [-] Driving mode = active [-] continuous 5, 370 [ms] 2 DCY
  U044C Invalid data received from control module for contact-less charging Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 770 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 8 repetitions [-] Autonomous HV request = commanded on [-] continuous 1, 970 [ms]
  U0413 Invalid data received from Battery Energy Control Module "B" Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 390 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 31 repetitions [-] Autonomous HV request = commanded on [-] continuous 680 [ms]
  U0413 Invalid data received from Battery Energy Control Module "B" Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 1, 370 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 5 repetitions [-] Autonomous HV request = commanded on [-] continuous 2, 870 [ms]
  U0411 Invalid data received from Drive Motor Control Module "A" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 470 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 25 repetitions [-] Autonomous HV request) = commanded on [-] continuous 1, 620 [ms]
          Driving mode = not active [-]      
  U0411 Invalid data signal received from Drive Motor Control Module "A" Invalid checksum ≥ 2 consecutive [-] (Ignition = on [-] continuous 1, 370 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 5 repetitions [-] Autonomous HV request) = commanded on [-] continuous 2, 870 [ms]
          AND          
          Driving mode = not active [-]      
  U049C Invalid data received from Battery Charger Control Module "A" Invalid checksum ≥ 2 consecutive [-] Ignition = on [-] continuous 570 [ms] 1 DCY
    OR     OR          
    Message counter ≥ 10 repetitions [-] Autonomous HV request = commanded on [-] continuous 1, 370 [ms]
  U044C Implausible signal received from control module for contact-less charging Wireless HV charging module error state signal = init [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U0413 Implausible signal received from Battery Energy Control Module "B" HV battery current state signal = init [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Implausible signal received from Battery Energy Control Module "B" HV battery error state signal = init [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Implausible signal received from Battery Energy Control Module "B" HV battery voltage signal = init [V] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0411 Implausible signal received from Drive Motor Control Module "A" HV voltage converter HV side voltage signal = init [V] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0411 Implausible signal received from Drive Motor Control Module "A" Power electronics error state signal = init [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U049C Implausible signal received from Battery Charger Control Module "A" HV charger current state signal = init [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    HV charging mode = active [-]
    Driving mode = not active [-]
  U049C Implausible signal received from Battery Charger Control Module "A" HV charger error state signal = init [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]

Table continues below

Component / System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value Unit Secondary Parameters Enable Condition Unit Monitor Frequency of Checks Monitoring Time Length Unit MIL Illum.
            Driving mode = not active [-]        
  U0413 Data bus error value received from Battery Energy Control Module "B" Information content HV battery = error [-] Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Data bus error value received from Battery Energy Control Module "B" Information content HV battery = no component function [-] Ignition = on [-] continuous 920 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Data bus error value received from Battery Energy Control Module "B" Information content HV battery = service disconnect [-] Ignition = on [-] continuous 920 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Data bus error value received from Battery Energy Control Module "B" Information content HV battery = interlock [-] Ignition = on [-] continuous 920 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Data bus error value received from Battery Energy Control Module "B" Information content HV battery = invalid voltage value [V] Ignition = on [-] continuous 2, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0411 Data bus error value received from Drive Motor Control Module "A" Information content HV converter = invalid voltage value on HV side [V] Ignition = on [-] continuous 2, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U049C Data bus error value received from Battery Charger Control Module "A" Information content HV charger = error [-] (Ignition = on [-] continuous 5, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    HV charging mode = active [-]
    Driving mode = not active [-]
  U049C Data bus error value received from Battery Charger Control Module "A" Information content HV charger = no component function [-] (Ignition = on [-] continuous 1, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U049C Data bus error value received from Battery Charger Control Module "A" Information content HV charger = interlock [-] (Ignition = on [-] continuous 870 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U044C Data bus error value received from control module for contact-less charging Information content wireless HV charging module = no component function [-] (Ignition = on [-] continuous 2, 370 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U044C Data bus error value received from control module for contact-less charging Information content wireless HV charging module = interlock [-] (Ignition = on [-] continuous 870 [ms] 1 DCY
    OR    
    Autonomous HV request) = commanded on [-]
    Driving mode = not active [-]
  U0411 Data bus error value received from Drive Motor Control Module "A" Information content power electronics = interlock [-] Ignition = on [-] continuous 870 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0413 Data bus error value received from Battery Energy Control Module "B" Absolute difference between the voltage measured at HV battery and the HV side voltage measured at voltage converter > 50 [V] Ignition = on [-] continuous 3, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
  U0411 Data bus error value received from Drive Motor Control Module "A" Absolute difference between the voltage measured at HV battery and the HV side voltage measured at voltage converter > 50 [V] Ignition = on [-] continuous 3, 370 [ms] 1 DCY
    OR    
    Autonomous HV request = commanded on [-]
flex ray U0100 Lost communication with ECM/PCM "A" (time out) Message time out = detected [-] Driving mode = active [-] continuous 5, 370 [ms] 2 DCY
Gateway internal control module U0447 Invalid data received from Gateway "A" (EEPROM error) CASE 1:     none   [-] once/DCY 500 [ms] 1 DCY
    Read pattern = not successful [-]
    Timer > 5 [s]
         
    CASE 2:    
    Read pattern = successful [-]
    Write pattern = not successful [-]
    Timer > 5 [s]
  U0447 Invalid data received from Gateway "A" (RAM error) Checksum error = detected [-] none   [-] multiple 5, 000 [ms] 1 DCY
  U0447 Invalid data received from Gateway "A" (ROM error) Checksum error = detected [-] none   [-] multiple 5, 000 [ms] 1 DCY
  U0447 Invalid data received from Gateway "A" (watchdog error) SBC test = passed [-] none   [-] continuous 5, 000 [ms] 1 DCY
    (External reset != detected [-]
    OR    
    Watchdog trigger) != reported by the SBC [-]