LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> S6 Premium Plus >> Repair and Diagnosis (Single Page) >> Maintenance >> Procedures >> General Maintenance (1 Of 2) >> Maintenance >> Procedure Descriptions >> Battery Fluid Level, Checking >> Battery With Visual Indicator

Battery With Visual Indicator

WARNING:

Warning information for the high voltage system:

For procedures where the ignition must be switched off, refer to PROCEDURES FOR WHICH THE IGNITION NEEDS TO BE SWITCHED OFF .

NOTE:

Applies only to the auxiliary battery in hybrid vehicles.

The auxiliary battery A1 is located in the spare wheel well near battery A. Refer to HIGH VOLTAGE COMPONENTS AND CABLES OVERVIEW .

Batteries with or without visual indicator must not be opened.

-- Remove the bubbles under the "visual indicator" by lightly and carefully tapping the "visual indicator" -arrow- with the handle of a screwdriver.

GWWA27-0086Courtesy of AUDI OF AMERICA, LLC
   

Read the battery electrolyte level present in the color display. Two different displays are possible:

Color display Battery level
Black or green
  • Battery electrolyte level OK
Colorless or light yellow
  • Battery electrolyte level too low. Risk of explosion, do not check or charge the battery.
WARNING:

Risk of explosion by charging the battery with "visual indicator".

If the "visual indicator" is colorless or light yellow, do not check or charge the battery. Do not try to jump start it! There is a risk of explosion when checking, charging, or jumping the battery. The battery must be replaced! .