Windshield Projection Head Up Display Control Module, Calibrating

Special Tools And Workshop Equipment Required 

Conditions 

-- The windshield projection control module must be calibrated during the following conditions:

GWWA90-10185Courtesy of AUDI OF AMERICA, LLC

-- Move the vehicle onto a secure flat surface.

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Fold down the left and right sun visors, disengage them and move them to the side.

-- Engage the Head-Up Display Calibration Board - Audi A7 :VAS6656  on the sun visor center support -1 and 2-.

Performing Calibration 

Vehicle Diagnostic Tester is attached.

-- Select the Diagnostic  mode and start the diagnostics.

-- Select the tab Test Plan  .

-- Select Select Individual Tests  and choose the following sequence.

From here the Vehicle Diagnostic Tester advances the calibration procedure forward.

-- After calibrating the windshield projection head up control module successfully, end "calibration", turn off the ignition and disconnect the diagnostic connector.