Rearview Camera, Calibrating
-- Establish the requirements. Refer to Calibration Requirements .
-- Connect the Vehicle Diagnostic Tester.
Calibration Tool - Wheel Center Mountings:VAS6350/1 installing:
-- Check the dimension of the holes.
-- Equip the Calibration Tool - Wheel Center Mountings:VAS6350/1 appropriately. Use spacer pieces.
-- To do so, secure the three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings :VAS6350/1 .
-- Place the paddle on both Calibration Tool - Wheel Center Mountings :VAS6350/1 and secure them using a clamping screw.
-- Place the Calibration Tool - Wheel Center Mountings :VAS6350/1 onto the wheel bolts on the rear wheels.
The Calibration Tool - Wheel Center Mountings :VAS6350/1 are positioned by the "O-rings" in the adapters and secured.
Attach the Calibration Tool - Wheel Center Mountings :VAS6350/1 onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the Calibration Tool - Wheel Center Mountings :VAS6350/1 .
-- Adjust the paddles with aid of lock bolts so that they move freely just above the floor. Check the paddles for ease of movement.
-- Install and align the Calibration Unit :VAS6350A . Refer to Calibration Unit .
Distance measurement:
-- Switch on the Calibration Tool - Spacing Laser :VAS6350/2 .
The Following Display Appears:
The display shows how to stop the Calibration Tool - Spacing Laser :VAS6350/2 . Press the corresponding button.
- Attach with Front Edge
- Attach with Rear Edge
-- Hold the Calibration Tool - Spacing Laser :VAS6350/2 -2- flush in the bracket on one side of the calibration board (attach with rear edge). The Calibration Tool - Spacing Laser :VAS6350/2 -2- must sit securely on the bracket.
-- Press the measuring button briefly.
The laser switches on.
-- Make sure that laser beam from Calibration Tool - Spacing Laser :VAS6350/2 -2- hits the lower, enlarged part of paddle -1-.
If this is not the case, correct the paddles accordingly via clamping screws on the Calibration Tool - Wheel Center Mountings:VAS6350/1 .
-- Use one hand to secure the Calibration Tool - Spacing Laser :VAS6350/2 in the bracket on the Calibration Tool:VAS6350 while the laser beam is visible on the paddle.
-- Then press the measurement button for the distance measurement briefly.
-- Write down the value.
-- Repeat this measurement on the other side of the Calibration Tool :VAS6350 in the same way for the rear wheel.
The distance value must be the same on both sides.
If values are not identical:
-- Align the Calibration Unit :VAS6350A long enough so that both sides are identical.
Pay attention when aligning the Calibration Tool :VAS6350 , that the Calibration Tool - Linear Laser :VAS6350/3 from the Calibration Tool :VAS6350 strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.
Dimension measurement -H- :
-- Measure the height of the Calibration Tool:VAS6350 , dimension -H- (top edge platform - floor).
Make sure the Calibration Tool - Spacing Laser:VAS6350/2 is adjusted correctly (attach with front edge).
The display shows how to stop the Calibration Tool - Spacing Laser:VAS6350/2 . Press the corresponding button.
- Attach with Front Edge
- Attach with Rear Edge
Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".
Calibrating
The Vehicle Diagnostic Tester is connected.
-- Select the Diagnostic mode and start the diagnosis.
-- Select the Test plan tab.
-- Press the Select individual tests button and select the following one after the other:
- Body
- Electrical system
- 01 - OBD-capable systems
- 6C - Rearview camera system control module - J772
- 6C - Rearview camera system, functions
- 6C - Calibrating
From here, the Vehicle Diagnostic Tester advances the calibration procedure forward.