Rearview Camera, Calibrating

-- Establish the requirements. Refer to Calibration Requirements .

-- Connect the Vehicle Diagnostic Tester.

Calibration Tool - Wheel Center Mountings:VAS6350/1  installing:

-- Check the dimension of the holes.

-- Equip the Calibration Tool - Wheel Center Mountings:VAS6350/1  appropriately. Use spacer pieces.

-- To do so, secure the three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings :VAS6350/1  .

-- Place the paddle on both Calibration Tool - Wheel Center Mountings :VAS6350/1  and secure them using a clamping screw.

-- Place the Calibration Tool - Wheel Center Mountings :VAS6350/1  onto the wheel bolts on the rear wheels.

The Calibration Tool - Wheel Center Mountings :VAS6350/1  are positioned by the "O-rings" in the adapters and secured.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the Calibration Tool - Wheel Center Mountings :VAS6350/1  onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the Calibration Tool - Wheel Center Mountings :VAS6350/1  .

-- Adjust the paddles with aid of lock bolts so that they move freely just above the floor. Check the paddles for ease of movement.

-- Install and align the Calibration Unit :VAS6350A  . Refer to Calibration Unit .

Distance measurement:

-- Switch on the Calibration Tool - Spacing Laser :VAS6350/2  .

The Following Display Appears:

Fig 2: Identifying Display Showing How To Stop Calibration Tool
GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the Calibration Tool - Spacing Laser :VAS6350/2  . Press the corresponding button.

Fig 3: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with Front Edge
  2. Attach with Rear Edge

-- Hold the Calibration Tool - Spacing Laser :VAS6350/2  -2- flush in the bracket on one side of the calibration board (attach with rear edge). The Calibration Tool - Spacing Laser :VAS6350/2  -2- must sit securely on the bracket.

Fig 4: Ensuring Laser Beam From Distance Laser VAS 6350/2 Hits Lower, Enlarged Part Of Paddle
GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Press the measuring button briefly.

The laser switches on.

-- Make sure that laser beam from Calibration Tool - Spacing Laser :VAS6350/2  -2- hits the lower, enlarged part of paddle -1-.

If this is not the case, correct the paddles accordingly via clamping screws on the Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Use one hand to secure the Calibration Tool - Spacing Laser :VAS6350/2  in the bracket on the Calibration Tool:VAS6350  while the laser beam is visible on the paddle.

-- Then press the measurement button for the distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the Calibration Tool :VAS6350  in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical:

-- Align the Calibration Unit :VAS6350A  long enough so that both sides are identical.

Pay attention when aligning the Calibration Tool :VAS6350  , that the Calibration Tool - Linear Laser :VAS6350/3  from the Calibration Tool :VAS6350  strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.

Dimension measurement -H- :

-- Measure the height of the Calibration Tool:VAS6350  , dimension -H- (top edge platform - floor).

Fig 5: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Make sure the Calibration Tool - Spacing Laser:VAS6350/2  is adjusted correctly (attach with front edge).

The display shows how to stop the Calibration Tool - Spacing Laser:VAS6350/2  . Press the corresponding button.

Fig 6: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with Front Edge
  2. Attach with Rear Edge

Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".

Calibrating

The Vehicle Diagnostic Tester is connected.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Press the Select individual tests  button and select the following one after the other:

From here, the Vehicle Diagnostic Tester advances the calibration procedure forward.