Rearview Camera -R189-, CALIBRATING

Special tools and workshop equipment required 

-- Establish the requirements. Refer to Calibration Requirements .

-- Connect Vehicle Diagnostic Tester.

: VAS6350/1  installing:

-- Check which hole circle the rims have.

-- Equip the : VAS6350/1  appropriately.

-- To do so, secure the three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings: VAS6350/1  .

-- Place the paddle on both : VAS6350/1  and secure them using a clamping screw.

-- Place the : VAS6350/1  onto the wheel bolts on the rear wheels.

The : VAS6350/1  are positioned by the "O-rings" in the adapters and secured.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the : VAS6350/1  onto the wheels so that any installed "anti-theft" wheel bolts are not connected to the : VAS6350/1  .

-- Adjust the paddles with the aid of clamping screw so that they move freely just above the floor. Check the paddles for ease of movement.

-- Install and align the : VAS6350A  . Refer to Calibration Unit .

Distance measurement:

-- Switch on the : VAS6350/2  .

The Following Display Appears

Fig 2: Identifying Display Showing How To Stop Calibration Tool
GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the : VAS6350/2  . Press the corresponding button.

Fig 3: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with the front edge.
  2. Attach with the rear edge.

-- Hold the : VAS6350/2  -2- flush in the bracket on one side of the calibration board as shown. The : VAS6350/2  -2- must sit securely on the bracket at the same time.

Fig 4: Ensuring Laser Beam From Distance Laser VAS 6350/2 Hits Lower, Enlarged Part Of Paddle
GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Push the measurement button briefly.

The laser switches on.

The laser beam from the : VAS6350/2  -2- must hit the lower, enlarged section of the paddle -1-.

If this is not the case, the paddles must be corrected accordingly via clamping screws on the : VAS6350/1  .

-- Use one hand to secure the : VAS6350/2  in the bracket on the : VAS6350  while the laser beam is visible on the paddle.

-- Then press the measurement button for the distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the : VAS6350  in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical:

-- Align the : VAS6350A  long enough so that both sides are identical.

-- When adjusting, make sure the : VAS6350/3A  strikes the center above the Audi rings and that the level indicator remains centered. Adjust if necessary.

Dimension measurement -H- :

-- Measure the height of the : VAS6350A  , dimension -H- (top edge platform - floor).

Fig 5: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Make sure the : VAS6350/2  is adjusted correctly (attach with front edge).

The display shows how to stop the : VAS6350/2  . Press the corresponding button.

Fig 6: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with the front edge.
  2. Attach with the rear edge.

Enter the height and distance dimensions into Vehicle Diagnostic Tester in "millimeters".

Calibrating Procedure

The Vehicle Diagnostic Tester is connected.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

From here, the Vehicle Diagnostic Tester advances the calibration procedure forward.

WARNING:

Make sure light does not reflect off the calibration board.

Reflections impair the Rearview Camera -R189- and may make it impossible to perform the calibration.