Data Bus On Board Diagnostic Interface -J533-: Removing
-- Remove the rear seat bench. Refer to REAR BENCH SEAT .
-- Fold back the front of the insulation mat.
-- Remove the nuts -arrows-, if equipped.
-- Remove the Data Bus on board diagnostic interface -3- from the threaded pins.
-- Disconnect the connector -5- and the connector -4- for the fiber-optic cable.
NOTE:
If the ground wire -1- is above the mount on the Data Bus on board diagnostic interface as shown, then it must be loosened on the ground distributor -2-.
-- Seal open wiring harness fiber optic connector -2- with Protective Cap For Cable Connector VAS 6223/9 -item 1-.
NOTE:
Protective cap prevents contamination of or mechanical damage to end face of fiber optic cable which would impair signal transmission.
-- To disconnect electrical connector, press catch -1-, turn retaining bracket in -direction of arrow- and remove connector.