Ignition Coils
Special tools and workshop equipment required
- Ignition Coil Puller T40039
Removing
-- Disconnect the connector -6- from Camshaft Position (CMP) sensor 3 -G300-.
-- Remove the bolts -arrows-.
-- Release the connectors and remove them from the ignition coils -1 through 5-.
-- Push the T40039 onto the ignition coil with power output stage and remove the ignition coil -arrow-.
Installing
-- Install all the ignition coils loosely into the spark plug shaft.
-- Align and connect the ignition coils to the connectors all at the same time.
-- Push the ignition coils evenly onto the spark plugs by hand (do not use a hammer).
-- Attach the ignition coil wiring guide to the cylinder head cover. Refer to Figure.