Check Valve, Checking
NOTE:
The check valve is tightly installed in the vacuum hose.
To check it, the vacuum hose must be removed.
Valve must allow air to flow in direction of -arrow-.
Valve must remain closed in opposite direction.
Observe correct installation position.
The flow direction arrow faces the vacuum pump.