LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> A8 Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> 4.2L - Generic Scan Tool - Engine Code: CDRA (2 Of 2) >> St Generic Scan Tool >> Diagnosis And Testing >> Diagnostic Procedures >> Heated Oxygen Sensor HO2S, Checking

Heated Oxygen Sensor HO2S, Checking

Observe all safety precautions: SAFETY PRECAUTIONS

View clean working conditions: CLEAN WORKING CONDITIONS

For wiring diagrams, component locations, and connector views, Refer to the applicable wiring diagram.

NOTE:

Use only gold-plated terminals when servicing terminals in the electrical harness connector of the Heated Oxygen Sensor (HO2S) -G39-.

Special Tools And Workshop Equipment Required 

Test requirements

Test procedure

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK

Start diagnosis

-- Connect scan tool.

-- Start the engine and let it run at idle.

-- Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

-- Select "Test-ID 01: Oxygen sensor monitoring before catalytic converter".

-- Select "Test-ID 131: Dynamic test".

-- Check the specified values at idle.

Dynamic test Specified value
  min. max.
Normal operation 0.35009 -
Reduced threshold upon suspicion of malfunction in catalytic converter 0.39990 -

If specified values are obtained:

-- End diagnosis and switch the ignition off.

If the specified values are not obtained:

Checking primary voltage

-- Disconnect the Heated Oxygen Sensor (HO2S) -G39- electrical harness connector -1-.

Fig 2: Identifying Heated Oxygen Sensor (HO2S) G39 Electrical Harness Connector
GWWM24-0425Courtesy of AUDI OF AMERICA, LLC

-- Using a multimeter, check the Heated Oxygen Sensor (HO2S) -G39- electrical harness connector -1- terminals 1 to 5 for voltage.

Fig 3: Identifying 6-Pin Electrical Harness Connector & Terminals
GWWM24-0435Courtesy of AUDI OF AMERICA, LLC

Specified value: 0.4 to 2 Volts

-- Switch the ignition off.

If the specified value was not obtained:

-- Replace the Heated Oxygen Sensor (HO2S) -G39-. Refer to the appropriate service information.

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-- Install the test box.

If the manufacturers test box is not being used, perform the following step.

-- Remove the Motronic Engine Control Module (ECM) -J623-. Refer to the appropriate service information.

-- Using a multimeter, check the Heated Oxygen Sensor (HO2S) -G39- electrical harness connector terminals to the Motronic Engine Control Module (ECM) -J623- electrical harness connector T91 terminals for an open circuit.

Fig 4: Identifying 6-Pin Electrical Harness Connector & Terminals
GWWM24-0435Courtesy of AUDI OF AMERICA, LLC
Heated Oxygen Sensor (HO2S) -G39- electrical harness connector terminals Motronic Engine Control Module (ECM) -J623- electrical connector T91 terminals
1 7
2 8
3 22
4 fuse SA 10
5 10

Specified value: 1.5 Ω Max.

If the specification was not obtained:

-- Check the wiring for a short circuit to Battery (+), or an open circuit.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

If no malfunction is found in the wiring:

-- Replace the Motronic Engine Control Module (ECM) -J623-. Refer to the appropriate service information.

Final procedures

After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .