Calibration Requirements
- The camera lens must be clean. Cleaning
- The vehicle must be standing on a firm and level surface.
- There must be enough clearance around the vehicle (at least 2 meters).
- The parking brake must be set.
- The steering wheel must be in the 0 position and the wheels must be straight.
- All doors and the rear lid must be closed.
- No one should be in the vehicle.
- The vehicle must not be loaded (curb weight).
- Connect the battery charger.
- Ignition switched on.
Special tools and workshop equipment required
- Calibration ToolVAS6350
- Vehicle Diagnostic Tester
The Calibration ToolVAS6350 consists of the following parts:
- Calibration Tool - Wheel Center MountingsVAS6350/1
- Calibration Tool - Spacing LaserVAS6350/2
- Linear LaserVAS6350/3A