LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> A7 >> Repair and Diagnosis >> External Pages >> Different car >> Section 25 (Communication) >> 91 Communication >> Rearview Camera System >> Rearview Camera System, Calibrating >> Rearview Camera, Calibrating

Rearview Camera, Calibrating

WARNING: This page is about a different car, the 2015 Audi A7 Quattro and 2014 Audi A7 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

-- Set-up requirements, refer to Calibration Tool VAS 6350, INSTALLING AND ALIGNING .

-- Connect the Vehicle Diagnostic Tester.

Calibration Tool - Wheel Center Mountings VAS 6350/1 installing: 

-- Check the dimension of the holes.

-- Equip the Calibration Tool - Wheel Center Mountings VAS 6350/1 appropriately. Use spacer pieces.

-- To do so, secure three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings VAS 6350/1.

-- Place the paddle on both Calibration Tool - Wheel Center Mountings VAS 6350/1 and secure them using a clamping screw.

-- Place the Calibration Tool - Wheel Center Mountings VAS 6350/1 onto the wheel bolts on the rear wheels.

The Calibration Tool - Wheel Center Mountings VAS 6350/1 are positioned by the "O rings" in the adapters and held in place.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the Calibration Tool - Wheel Center Mountings VAS 6350/1 onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the Calibration Tool - Wheel Center Mountings VAS 6350/1.

-- Adjust the paddle with aid of lock bolts so that they move freely just above the floor. Make sure that the paddle is easily accessible.

-- Install and align the Calibration Tool VAS 6350. Refer to Calibration Tool VAS 6350, INSTALLING AND ALIGNING .

Distance measurement: 

-- Switch on the Calibration Tool - Spacing Laser VAS 6350/2.

Fig 2: Identifying Display Showing How To Stop Calibration Tool
GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the Calibration Tool - Spacing Laser VAS 6350/2. Press the corresponding button.

Fig 3: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

-- Hold the Calibration Tool - Spacing Laser VAS 6350/2 -2- flush in the bracket on one side of the calibration board (attach with rear edge). The Calibration Tool - Spacing Laser VAS 6350/2 -2- must sit securely on the bracket.

Fig 4: Ensuring Laser Beam From Distance Laser VAS 6350/2 Hits Lower, Enlarged Part Of Paddle
GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Press the measuring button briefly.

The laser turns on.

-- Make sure that laser beam from Calibration Tool - Spacing Laser VAS 6350/2 -2- hits lower, enlarged part of paddle -1-.

If this is not the case, correct the paddles accordingly via clamping screws on the Calibration Tool - Wheel Center Mountings VAS 6350/1.

-- Use one hand to secure the Calibration Tool - Spacing Laser VAS 6350/2 in the bracket on the Calibration Tool VAS 6350 while the laser beam is visible on the paddle.

-- Then press the measuring button for distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the Calibration Tool VAS 6350 in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical: 

-- Align the Calibration Tool VAS 6350 long enough so that both sides are identical.

Pay attention when aligning the Calibration Tool VAS 6350, that the Calibration Tool - Linear Laser VAS 6350/3 from the Calibration Tool VAS 6350 strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.

Dimension measurement -H- : 

-- Measure the height of the Calibration Tool VAS 6350, dimension -H- (top edge platform - floor).

Fig 5: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Make sure the Calibration Tool - Spacing Laser VAS 6350/2 is adjusted correctly (attach with front edge).

The display shows how to stop the Calibration Tool - Spacing Laser VAS 6350/2. Press the corresponding button.

Fig 6: Identifying Front Edge And Rear Edge
GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".

Performing calibration

Vehicle Diagnostic Tester is attached.

-- Select the Diagnostic  mode and start the diagnostics.

-- Select the tab test plan  .

-- Select select individual tests  and choose the following sequence.

The Vehicle Diagnostic Tester continues with the calibrating procedure from here on.

WARNING:

Make sure light does not reflect off the calibration platform.

Reflections affect the Rearview Camera -R189- and may make it impossible to perform the calibration.