| P0603 |
Internal Control Module Keep Alive Memory (KAM) Error |
- The diagnostic is monitoring EEPROM checksums and hardware failures of the Flash Control Unit
|
- Number of sector groups with valid checksum < 2
OR
- Read or write operation not possible (Flash Control Unit defective) = true
|
|
- An EEPROM read or write operation has occurred = true
|
|
|
| P0605 |
Internal Control Module Read Only Memory (ROM) Error |
- A checksum is calculated for each memory block and compared with a stored reference checksum
|
- Calculated checksum unequal to reference checksum = true
|
|
- TCM is in power-on state = true
|
|
|
| P060A |
Internal Control Module Monitoring Processor Performance |
- Calculation check of input speed for functional use
|
- Difference in calculation of input speed for functional use and monitoring use > 650 RPM
|
|
- No failure detected in sensor voltage supply = True
- No failure detected in output speed and n6 speed monitoring True
- No failure detected in engine speed CAN message True
|
|
|
|
|
- inhibit path test of safety relevant power supplies during init failed
|
|
|
|
|
- monitoring of the DN reset line failed
|
|
|
|
|
|
- hardware doesn't report any error although the peripheral clock is switched off
OR
- peripheral is switched on and the re are hardware error reports for at least two cycles
|
|
- peripheral clock active
- delay time passed
|
|
|
|
- failure in program flow control
|
|
|
|
|
|
- SW - or configuration fault in WDOG SW-Module
|
|
|
|
|
|
- a ASIC status failure has been detected
|
|
|
|
- a monitored module status failure has been detected
|
|
|
|
| P060B |
Internal Control Module A/D Processing Performance |
|
- measured ADC signals inconsistent to configured voltage limits or other hardware signals
|
|
|
|
|
|
|
|
- "RAM ECC monitoring, RAM ECC interrupt monitoring, ROM ECC monitoring"
|
|
- CPU configuration register monitoring
|
- content of registers inconsistent to the requested values
|
| P0613 |
TCM Processor |
|
- signal read back from the CAN Bus 2 is unequal to the send out signal
|
|
- no failure detected on CAN Bus 2
|
|
|
|
|
- two signals representing the same value but calculated in two different ways are unequal
|
|
| P0667 |
Control Module Internal Temperature Sensor "A" Range/Performance |
|
- Voltage at sensor plus pin U pin hi > 4.7 V
- Voltage at sensor plus pin U pin hi < 0.508 V
- Voltage at sensor minus pin U pin lo > 0.423 V
- Voltage at sensor minus pin U pin lo < 0.005 V
- Difference voltage at sensor pins U sensor > 4.512 V
- Difference voltage at sensor pins U sensor < 0.135 V
- Resistor ratio U supply - U sensor / U pin lo > 15.5
- Resistor ratio U supply - U sensor) / U pin lo < 10
|
|
|
|
|
|
|
- Transmission oil temperature delta between 2 measurements > 20 °C
|
|
- No failure detected in Other oil temperature sensor monitors
|
|
|
|
IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip 1 temperature value and oil temperature value and Chip 2 temperature value > 15 °C
|
|
- No failure detected in Other oil temperature sensor monitors
- No failure detected in Input speed signal and engine speed signal
- Engine speed or input speed > 400 RPM and >= 300 s
|
|
|
IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip 1 temperature value and oil temperature value and Chip 2 temperature value > 30 °C
|
|
|
|
|
- Out of range low < - 45.9 °C
- Out of range high > 167.8 °C
|
|
|
|
|
|
- Plausibility to internal comparator outputs violated
|
|
|
|
|
- Absolute differences between Chip 1 and Chip 2 temperature value > 10 °C
AND IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip 1 temperature value > 15 °C
IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip1 temperature value > 30 °C
|
|
- No failure detected in Other oil temperature sensor monitors
- No failure detected in Input speed signal and engine speed signal
- Engine speed or input speed > 400 RPM and >= 300 s
|
|
|
|
|
- Out of range low < -45 °C
- Out of range high > 192 °C
|
|
|
|
|
|
|
|
|
|
|
- Absolute differences between Chip 1 and Chip 2 temperature value > 10 °C
AND IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip 2 temperature value > 15 °C
IN THERMODYNAMIC STABLE CONDITIONS: (Absolute differences between)
- Oil temperature value and Chip 2 temperature value > 30 °C
|
|
- No failure detected in Other oil temperature sensor monitors
- No failure detected in Input speed signal and engine speed signal
- Engine speed or input speed > 400 RPM and >= 300 s
|
|
|
| P0715 |
ISO/SAE Reserved Input Turbine/Speed Sensor "A" Circ. |
|
- ASIC CG124 indicates open circuit or short to ground = True
|
|
- No failure detected in sensor voltage supply = True
|
|
|
| P0716 |
Input/Turbine Shaft Speed Sensor "A" Circuit Range/Performance |
- Double failure monitoring to determine more than one defective sensor
|
- More than one of the following speed signals are defective: n6 speed, output speed or wheel speed
|
|
- No failure detected in sensor voltage supply = True
- Engine speed > 430 RPM
- No failure detected in engine speed CAN message = True
|
|
|
- Double failure monitoring of engine speed signal and n6 speed signal
|
- Any failure on engine speed signal from CAN = True
- n6 speed signal is invalid because of an electrical or rationality failure = True
|
- No failure detected in sensor voltage supply = True
|
- Double failure monitoring of output speed signal and wheel speed signal
|
- Absolute difference between output speed and output speed calculated from wheel speed > 350 RPM
|
- No failure detected in sensor voltage supply = True
- Gear shift in progress = True
- Engine speed > 450 RPM
- No failure detected in engine speed CAN message = True
|
| |
- Rationality to other sensor speed signals
|
- Rationality to other sensor speed signals > 250 RPM
|
- No failure detected in sensor voltage supply, wheel speed signal or electrical n6 speed sensor monitoring = True
|
|
|
- Difference between measured output speed and output speed calculated from n6 speed > 250 RPM
|
- No failure detected in sensor voltage supply, output speed signal or electrical n6 speed sensor monitoring = True
|
| P0717 |
Input/Turbine Shaft Speed Sensor "A" Circuit No Signal |
|
- implausible direction of n6 speed sensor = True
|
|
- No failure detected in sensor voltage supply = True
|
|
|
| P0720 |
Output Shaft Speed Sensor Circuit |
|
- ASIC CG124 indicates open circuit or short to ground = True
|
|
- No failure detected in sensor voltage supply = True
|
|
|
| P0721 |
Output Shaft Speed Sensor Circuit Range/Performance |
- Rationality to other sensor speed signals
|
- Difference between measured output speed and output speed calculated from wheel speed > 350 RPM
|
|
- No failure detected in sensor voltage supply, wheel speed signal or electrical output speed sensor monitoring = True
|
|
|
- Difference between measured output speed and output speed calculated from n6 speed > 250 RPM
|
|
- No failure detected in sensor voltage supply, n6 speed signal or electrical output speed sensor monitoring = True
|
| P0730 |
Incorrect Gear Ratio |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s), an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold, output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| |
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold, output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
| P0746 |
Pressure Control Solenoid "A" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P0747 |
Pressure Control Solenoid "A" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0748 |
Pressure Control Solenoid "A" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits, depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits, depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P0749 |
Pressure Control Solenoid "A" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0750 |
Shift Solenoid "A" |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits, depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits, depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P0751 |
Shift Solenoid "A" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P0752 |
Shift Solenoid "A" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0754 |
Shift Solenoid "A" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0776 |
Pressure Control Solenoid "B" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P0777 |
Pressure Control Solenoid "B" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0778 |
Pressure Control Solenoid "B" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits, depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits, depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P0779 |
Pressure Control Solenoid "B" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P077C |
Output Shaft Speed Sensor Circuit Low |
|
- ASIC CG124 indicates short to battery voltage = True
|
|
- No failure detected in sensor voltage supply = True
|
|
|
| P0780 |
Shift Error |
|
- While shifting from gear X to gear Y the ratio is outside the defined limits is detected.
|
- actual ratio > gear X ratio + CC Ratio THUP x + CC Ratio OFTHUP xy
OR
- actual ratio < gear Y ratio - CC Ratio THLO y - CC Ratio_OFTHLO xy
|
UPSHIFT
- shifting from gear X to gear Y in progress
AND
DOWNSHIFT
- shifting from gear X to gear Y in progress
AND
|
|
|
| P0796 |
Pressure Control Solenoid "C" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- shifting from gear X to gear Y in progress
|
|
|
- short to ground or open pin
|
| P0797 |
Pressure Control Solenoid "C" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P0798 |
Pressure Control Solenoid "C" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits, depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits, depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P0799 |
Pressure Control Solenoid "C" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P07A5 |
Transmission Friction Element "B" Stuck On |
|
- clutch slip < CD Th Detect Slip
- check for engine load CD EngStall > CC Th DetectNoOpen eng"
- permanently true for CC ErrDelay NO
|
|
- position D or R
- gear 1 - 5 R
- no other error detected on drive clutch
- no Ratio monitoring error
- throttle <= CC Throttle
- break pressure > CC BreakP NO
- delay timer 'survey active > CC ActDelay
|
|
|
| P07AC |
Transmission Friction Element "F" Performance/Stuck Off |
- "Observe the combustion engine actual speed during the combustion engine starting procedure"
|
- actual combustion engine speed < 10 RPM
|
|
- Target clutch torque capacity > 200 Nm
- Actual electric motor speed >500 RPM
- Change from electric driving to hybrid driving commanded = True
|
|
|
| P07AD |
Transmission Friction Element "F" Stuck On |
- "Observe the combustion engine actual speed during the combustion engine starting procedure"
|
- actual combustion engine speed > 5 RPM
|
|
- Target clutch torque capacity > 0 Nm
- Actual combustion engine torque < 0 Nm
- Actual combustion engine speed gradient NGS VMK0OEFFNICHT DIHO RPM
- Change from hybrid driving to electric driving = True OR electric driving commanded = True
|
|
|
| P07BF |
Input/Turbine Shaft Speed Sensor "A" Circuit Low |
|
- ASIC CG124 indicates short to battery voltage = True
|
|
- No failure detected in sensor voltage supply = True
|
|
|
| P081E |
Excessive Clutch "B" Slippage |
|
- hybrid mode (combustion mod) > targeted engine rev. CC FRev NC
- engine speed CC Rev NC
- engine rev acceleration > CC RevAcc NC
- clutch slip > CC MaxSlip NC
- desired clutch torque > eng torque CC FTrq NC
|
|
- position D or R
- gear 1 - 5 R
- no gear change in progress
- wheel speed direction according to pos
- engine not in stall
- no other error detected on drive clutch
- no Ratio monitoring error
- gearbox temperature > CC MinTemp NC
- delay timer 'survey active > CC ActDelay
|
|
|
| P0863 |
TCM Communication Circuit |
|
- signal read back from the CAN Bus 1 is unequal to the send out signal
|
|
- no failure detected on CAN Bus 1
|
|
|
| P0C2F |
Internal Control Module Drive Motor/Generator - Engine Speed Sensor Performance |
|
|
|
- no failure detected on CAN Bus
AND
|
|
|
| P2637 |
Torque Management Feedback Signal "A" |
|
|
|
- no failure detected on CAN Bus
AND
|
|
|
| P2700 |
Transmission Friction Element "A" Apply Time Range/Performance |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s). an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold. output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| P2701 |
Transmission Friction Element "B" Apply Time Range/Performance |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s). an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold. output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| P2702 |
Transmission Friction Element "C" Apply Time Range/Performance |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s). an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold. output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| P2703 |
Transmission Friction Element "D" Apply Time Range/Performance |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s). an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold. output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| P2704 |
Transmission Friction Element "E" Apply Time Range/Performance |
|
- ratio detected is outside of defined limits. fault code for up to 3 corresponding clutches may be set. additional rationality checks using a substitute gear(s) is initiated. Depending on the behavior in the substitute gear(s). an additional fault code for only one or two clutches may be set to better distinguish the root cause of the problem.
|
|
GENERAL ENABLE CONDITIONS:
- oil-temperature > 0 °C
- engine speed > 400 RPM or if engine speed < threshold. output speed > 2500 RPM
- input speed > 0 RPM
- transmission lever position D or R
- timer elapsed > 200 ms
- no malfunction in input speed signal
- no malfunction in output speed signal
ADDITIONAL ENABLE CONDITIONS FOR GEARSHIFTS:
- output speed gradient > CC Ratio XYZ xy RPM
ADDITIONAL ENABLE CONDITIONS FOR ENGAGING GEARS:
- input speed gradient > 5000 RPM
- throttle > 5.09803921568628 %
|
|
|
| P270F |
Transmission Friction Element "F" Temperature Too High |
- Ensure if clutch slip remains in between predetermined limits
- observe the calculated clutch temperature
|
- "clutch slip "
- calculated clutch temperature
|
- > CC Th DetectOverSlip C0 RPM
- > CC Th DetectOverTemp C0 °C
|
- No failure detected in combustion engine speed and electric motor speed signals via CAN = True
- Target clutch pressure >1.5 bar
- Actual combustion engine torque <450 Nm
|
|
|
| P2714 |
Pressure Control Solenoid "D" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P2715 |
Pressure Control Solenoid "D" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2716 |
Pressure Control Solenoid "D" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits. depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits. depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P2717 |
Pressure Control Solenoid "D" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2723 |
Pressure Control Solenoid "E" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P2724 |
Pressure Control Solenoid "E" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2725 |
Pressure Control Solenoid "E" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits. depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits. depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P2726 |
Pressure Control Solenoid "E" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2732 |
Pressure Control Solenoid "F" Performance/Stuck Off |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
- short to ground or open pin
|
| P2733 |
Pressure Control Solenoid "F" Stuck On |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2734 |
Pressure Control Solenoid "F" Electrical |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits. depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits. depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P2735 |
Pressure Control Solenoid "F" Intermittent |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2808 |
Pressure Control Solenoid "G" Performance/Stuck Off |
- short to ground or open pin
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2812 |
Pressure Control Solenoid "G" Control Circuit/Open |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2813 |
Pressure Control Solenoid "G" Control Circuit Range/Performance |
|
- ASIC (SPI register) faulty
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
|
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current <= 0.85 - 0.12 A
- during shifting:
- measured current <= calculated limits. depending on incoming current gradient mA
|
|
|
- SW (calculation) feedback PWM
- no shifting:
- measured current >= 0.5 + 0.17 A
- during shifting:
- measured current >= calculated limits. depending on incoming current gradient mA
|
- SPI communication monitoring
|
- checkbyte of message wrong
- read back of sent message failed
- PWM feedback period > sync-period + 20 μs or < sync-period - 20 μs
|
| P2814 |
Pressure Control Solenoid "G" Control Circuit Low |
|
- ASIC (SPI register) faulty
- feedback (PWM) 100%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2815 |
Pressure Control Solenoid "G" Control Circuit High |
|
- ASIC (SPI register) faulty
- feedback (PWM) 0%
|
|
- power supply activated
- power supply voltage >= 6.5 V and < 19.2V
|
|
|
| P2873 |
Clutch "B" Pressure Engagement Too High |
|
- gearbox output shaft acceleration > CC Th DetectClosure acc
OR
- check for engine load CD EngStall > CC Th DetectClosure eng
|
|
- position D or R
- gear 1 - 5 R
- no gear change running
- no other error detected on drive clutch
- no Ratio monitoring error
- throttle <= CC Throttle
- break pressure > CC BreakP
- gearbox output rev < CC OutShaftSpeed C
- demanded clutch torque <= CC MaxTrq C
- delay timer 'survey active' > CC ActDelay
|
|
|
| U0001 |
High Speed CAN Communication Bus |
|
|
|
|
|
|
| U0002 |
High Speed CAN Communication Bus Performance |
|
- timeout for all received messages on A-CAN
|
|
AND
|
|
|
| U0028 |
Vehicle Communication Bus A |
|
|
|
|
|
|
| U0029 |
Vehicle Communication Bus A Performance |
|
- timeout for all received messages on H-CAN
|
|
AND
|
|
|
| U0100 |
Lost Communication With ECM/PCM "A" |
|
- message specific time expired
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|
| U0110 |
Lost Communication With Drive Motor Control Module "A" |
|
- message specific time expired
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|
| U0401 |
Invalid Data Received From ECM/PCM "A" |
- signal check
- signal activity check
- data field check
|
- checksum false
- alive counter doesn't count
- data length code false
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|
| U0411 |
Invalid Data Received From Drive Motor Control Module "A" |
- signal check
- signal activity check
- data field check
|
- checksum false
- alive counter doesn't count
- data length code false
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|
| U10E7 |
Manufacturer Controlled DTC Engine control module on hybrid CAN No communication |
|
- message specific time expired
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|
| U10E8 |
Manufacturer Controlled DTC Engine control module on hybrid CAN Implausible signal |
- signal check
- signal activity check
- data field check
|
- checksum false
- alive counter doesn't count
- data length code false
|
|
- no fault detected on CAN Bus
AND
AND
|
|
|