LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2009 >> S6 >> Repair and Diagnosis >> Engine Performance >> System >> 5.2L - Generic Scan Tool, Engine Code(S): BXA (St-Generic Scan Tool) >> ST - Generic Scan Tool >> Diagnostic Trouble Code (DTC) tables >> SAE P2xxx-DTCs >> Transmission

SAE P2xxx-DTCs: Transmission

DTC Error Message Diagnostic Procedure Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illum
P2637 Torque management Feedback Signal A CAN message signal error flag, = 1
  • Ignition, on
  • CAN Bus, OK
  • DME CAN connection, OK
0.5 Seconds
  • Continuous
  • 2 DCY
P2714 Pressure Control Solenoid D Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2715 Pressure Control Solenoid D Stuck On PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2716 Pressure Control Solenoid D Electrical
  • Current higher or lower than threshold, 730 mA
  • EDS output voltage at short to ground or open circuit ~ 0, 5 V smaller than EDS supply voltage
  • Static leakage current flow
  • Off operation mode
0.05 Seconds
  • Continuous
  • 2 DCY
P2723 Pressure Control Solenoid E Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2725 Pressure Control Solenoid "E" Electrical
  • Current higher or lower than threshold, 730 mA
  • EDS output voltage at short to ground or open circuit ~ 0, 5 V smaller than EDS supply voltage
  • Static leakage current flow
  • Off operation mode
0.05 Seconds
  • Continuous
  • 2 DCY
P2732 Pressure Control Solenoid F Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2733 Pressure Control Solenoid F Stuck On PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2734 Pressure Control Solenoid "F" Electrical
  • EDS output voltage at short to ground or open circuit ~ 0, 5 V smaller than EDS supply voltage
  • Static leakage current flow
  • Off operation mode
0.05 Seconds
  • Continuous
  • 2 DCY
P2735 Pressure Control Solenoid "F" Intermittent PWM hardware detection, 0 or 100%
  • Low side and high side FET, activated
  • Power supply, > 8.7 V
  • Voltage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY