LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2007 >> A6 Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (4.2L - Generic Scan Tool, Engine Code(S): BVJ (St-Generic Scan Tool)) >> ST - Generic Scan Tool >> Diagnostic Trouble Code Tables >> SAE P1xxx DTCs >> Engine

SAE P1xxx DTCs: Engine

WARNING: This page is about a different variant/trim than selected.
DTC Error Message Diagnostic Procedure Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illum
P12A1 Fuel Rail Pressure Sensor High Pressure System
  • Pressure control activity >0.18MPa
  • Fuel trim activity 0.85
  • Lambda control, Closed loop
  • EVAP purge flow, 1 kg/h
  • Engine speed, 500900 RPM
  • Engine load, 1027%
  • Fuel cut off, Not active
5 Seconds
  • Continuous
  • 2 DCY
P12A2 Fuel Rail Pressure Sensor High Pressure System
  • Pressure control activity -0.2 MPa
  • Fuel trim activity >1.3
  • Lambda control, Closed loop
  • EVAP purge flow, 1 kg/h
  • Engine speed, 600900 RPM
  • Engine load, 1027%
  • Fuel cut off, Not active
5 Seconds
  • Continuous
  • 2 DCY
P12A4 Fuel Rail Pressure Control valve
  • Pressure control activity -8.0 MPa
  • Fuel trim activity 0.951.3
  • Lambda control, Closed loop
  • EVAP purge flow, 1 kg/h
  • Engine speed, 600900 RPM
  • Engine load, 1027%
5 Seconds
  • Continuous
  • 2 DCY
P129B Fuel Pressure Regulator 2 Control Circuit Signal voltage 2.31 - 2.7 V
  • EVAP purge valve Commanded off
  • Engine relay, Commanded on
1 Second
  • Continuous
  • 2 DCY
P129C Fuel Pressure Regulator 2 Control Circuit Low Signal voltage 1.8- 2.25 V
  • EVAP purge valve Commanded off
  • Engine relay, Commanded on
1 Second
  • Continuous
  • 2 DCY
P129D Fuel Pressure Regulator 2 Control Circuit High Signal voltage >3.91 V
  • EVAP purge valve Commanded on
  • Engine relay, Commanded on
1 Second
  • Continuous
  • 2 DCY