| DTC | Error Message | Diagnostic Procedure | Malfunction Criteria and Threshold Value | Secondary Parameters with Enable Conditions | Monitoring Time Length | Frequency of checks, MIL Illum |
|---|---|---|---|---|---|---|
| P0601 | Internal Control Module Memory Check Sum Error |
|
Internal check sum, incorrect | 0.5 Seconds |
|
|
| P0602 | Control Module Programming Error |
|
Reprogramming not completed | 0.5 Seconds |
|
|
| P0604 | Internal Control Module Random Access Memory (RAM) Error |
|
Write ability check, failed | 0.5 Seconds |
|
|
| P0606 | ECM/PCM Processor |
|
|
|
10 Seconds 0.2 Seconds 0.5 Seconds |
|
| P0613 | TCM Processor |
|
Check-calculation of 1st CPU failed, Single reset does not cover problem | |||
| P0614 | ECM/TCM Incompatible |
|
Detection of error signal |
|
250 ms | |
| P062B | Injector Valves Communication CPU |
|
Engine speed, >80 RPM | 2 Seconds |
|
|
| P0638 | Throttle Actuator Control Range/Performance - Bank 1 |
|
|
|
5 Seconds |
|
| P0641 | Sensor Reference Voltage A Circuit/Open |
|
Internal Fault | 0.4 Seconds |
|
|
| P0642 | Sensor Reference Voltage A Circuit Low |
|
Signal voltage, 4.606-4.998 V | 0.4 Seconds |
|
|
| P0643 | Sensor Reference Voltage A Circuit High |
|
Signal voltage, >4.998-5.406 V | 0.4 Seconds |
|
|
| P0651 | Sensor Reference Voltage B Circuit/Open |
|
Internal Fault | 0.4 Seconds |
|
|
| P0652 | Sensor Reference Voltage B Circuit Low |
|
Signal voltage, 4.606-4.998 V | 0.4 Seconds |
|
|
| P0653 | Sensor Reference Voltage B Circuit High |
|
Signal voltage, >4.998-5.406 V | 0.4 Seconds |
|
|
| P0657 | Actuator Supply Voltage A Circuit/Open |
|
Signal voltage, > 4.4-5.6 V |
|
0.5 Seconds |
|
| P0658 | Actuator Supply Voltage A Circuit Low |
|
Signal voltage, 2.15-3.25 V |
|
0.5 Seconds |
|
| P0659 | Actuator Supply Voltage "A" Circuit High |
|
Signal current >1.1 A |
|
0.5 Seconds |
|
| P0685 | ECM/PCM Power Relay Control Circuit/Open |
|
|
|
0.5 Seconds |
|
| P0686 | ECM/PCM Power Relay Control Circuit Low |
|
|
|
0.5 Seconds |
|
| P0687 | ECM/PCM Power Relay Control Circuit High |
|
|
|
0.5 Seconds |
|
| P0688 | ECM/PCM Power Relay Sense Circuit |
|
|
|
1 Second 0.5 Seconds |
|
| P0697 | Sensor Reference Voltage C Circuit/Open |
|
Internal Fault | 0.4 Seconds |
|
|
| P0698 | Sensor Reference Voltage C Circuit Low |
|
Signal voltage, 4.606-4.998 V | 0.4 Seconds |
|
|
| P0699 | Sensor Reference Voltage C Circuit High |
|
Signal voltage, >4.998-5.406 V | 0.4 Seconds |
|