Drive Plate With Overload Protection, Checking Run-Out And Adjusting

-- Remove compressor.

-- Clean flange at drive plate -A-.

Fig 1: Checking/Adjusting Run-Out Of Drive Plate With Overload Protection
GWWA87-0624Courtesy of AUDI OF AMERICA, LLC

-- Secure a dial gauge -B- using a dial gauge holder -C- (for example using Dial Gauge HolderVW 387) on compressor.

-- Set probe of dial gauge -D- on flange of drive plate -A- with a pretension of approximately 1.0 mm.

-- Turn compressor drive unit -E- several rotations.

Specification: Runout deviation is less than 0.21 mm (runout of dial indicator, difference between smallest and largest measured value 0.2 mm maximum).

-- If runout deviation is greater than 0.2 mm, loosen bolts on drive plate. Refer to DRIVE PLATE WITH OVERLOAD PROTECTION  and readjust drive plate.