Diagnostic Mode 07: Check test results of components that are continuously monitored
WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
Diagnostic Mode 07 displays all stored DTCs of emission related components and systems which are continuously monitored.
NOTE:
- Depending on scan tool and protocol used, diagnostic mode 07 and the information provided may be referred to by a different name.
Test requirements
- No DTCs stored in the DTC memory.
- Coolant temperature at least 80°C.
Procedure
- Connect the scan tool.
- Start the engine and run at idle.
NOTE:
- If the engine does not start, crank the engine using starter for at least 5 seconds, do not switch the ignition off afterward under any circumstances.
- Select "Mode 7: Check test results of components that are continuously monitored".
The number of stored DTCs or "0 malfunctions detected" will be displayed scan tool screen.
- Switch the ignition off.
- Refer to the following DTC tables for the diagnostic repair procedure:
- SAE P0xxxDTCs → SAE P0xxx-DTCs .
- SAE P1xxx-DTCs → SAE P1xxx-DTCs .
- SAE P2xxxDTCs → SAE P2xxx-DTCs .
- SAE P3xxxDTCs → SAE P3xxx-DTCs .
- Switch the ignition off.
- End of diagnosis.