Diagnostic Mode 08 - Request Control of On-Board System, Test or Component
Diagnostic Mode 08 is used to control the operation of an on-board system, test or component. A Mode 8 service can be used to turn on-board system ON or OFF, or to cycle an on-board system, test or component ON or OFF for a specific period of time. The service can also be used to request system status or to report test results.
Diagnostic Mode 08, TID $01
Diagnostic Mode 08, TID $01 is used to determine if the evaporative system may be leaking.
NOTE:
- The Evaporative Emission (EVAP) Canister Purge Regulator Valve N80 - and Leak detection pump (LDP) V144 seal the tank system.
Test Prerequisites
- Coolant temperature must be 80 to 110 C → Diagnostic Mode 01 - Read Current System Data ; PID 5, Coolant temperature.
- Intake air temperature must not be above the maximum of 60 C → Diagnostic Mode 01 - Read Current System Data ; PID 15, Intake air temperature.
- Throttle valve angle 12.0 to 16.0% → Diagnostic Mode 01 - Read Current System Data ; PID 17: Throttle valve position (absolute)
Function Test
- Connect diagnostic tester → Diagnostic Tester, Connecting .
- Start engine and let run at least 15 minutes at idle.
- Under address word 33, select "Diagnostic mode 8: Tank leak test".
- Measuring value "Test-ID 01: select Tank leak test".
- Check specified value of tank leak test at idle.
| Test-ID 01: | Tank leak test | Specified value: | ||||
|---|---|---|---|---|---|---|
| Test function will be initiated Test function active Test off Test aborted No results | Test OK | |||||
NOTE:
- The function test can take a few minutes.
- If the accelerator pedal is depressed during the test, the test will be aborted.
- To repeat the tank leak test, switch ignition off and start engine again and let run 15 minutes at idle.
If specified value is obtained:
- End diagnosis and switch ignition off.
If specified value is not obtained:
- EVAP canister system, checking for proper seal → EVAP System Diagnostic Leak Test, Performing .
- Leak detection pump (LDP) V144 , checking → Leak Detection Pump, Checking .