| Engine Control Module (ECM) System identification |
Motronic ME 7 |
| |
| |
| Engine idle speed |
700-860 rpm |
| Engine speed (RPM) limitation |
approx. 6800 RPM |
| Ignition sequence |
1-3-4-2 |
| Ignition timing |
Not adjustable, regulated by Electronic control module |
| Ignition system |
Single coil ignition system with 4 ignition coils (output stages integrated) that are connected directly to spark plugs via the ignition cables. |
| Spark plugs |
101 905 600 |
| Manufacturer code |
PZFR5J-11 |
| Spark plug gap |
1.0 to 1.1 mm |
| Tightening torque |
25 Nm |