Work procedure
- Connect diagnostic tester. See Connect diagnostic tester .
- Start engine and let run at idle for at least 15 minutes.
- In diagnostic function "33 - OBD", select "Mode 6: Check test results of components that are not continuously monitored".
- Select the "Test-ID 05: Tank ventilation system".
- Check specified values at idle.TANK VENTILATION SYSTEM SPECIFICATION
Tank ventilation system Specification (1) Deviation of oxygen sensor control in direction "lean" min: 9830.000 Deviation of oxygen sensor control in direction "rich" min: 695,000 (1) Control module internal calculated value - End diagnosis and switch ignition off.
If the specified values are not reached:
- EVAP canister system, checking for proper seal. See EVAP CANISTER SYSTEM, CHECKING FOR PROPER SEAL .
- Check Leak Detection Pump (LDP) -V144-. See LEAK DETECTION PUMP (LDP) -V144-, CHECKING .